p.30
Wiring
Please add one diode as shown above. A fast recovery diode (Current: Min. 1A), 1
N4001 - 1N4007 or similar, is recommended.
Wiegand Data Connection (Applicable to Reader Mode)
●
Connect DATA0 IN wire of controller to TTL1/D0 (TTL Output1) wire of FINGER007 (Ora
nge with White stripe)
●
Connect DATA1 IN wire of controller to TTL2/D1 (TTL Output2) wire of FINGER007 (Bro
wn with White stripe)
If the controller and FINGER007 use separate power sources, you must connect th
e GND between the controller and FINGER007.
3.4
Reader Connections (External Reader)
Proximity Reader Connection
●
Connect (+) wire of FINGER007 to +12V (Red wire)
●
Connect (-) wire of FINGER007 to GND (Black wire)
●
Connect DATA0 wire of FINGER007 to DATA0 (Pink wire)
●
Connect DATA1 wire of FINGER007 to DATA1 (Cyan wire)
If the controller and the external reader use separate power sources, you must con
nect the GND between the controller and the external reader.
Compatible Readers(External Reader)
FINGER007 / IP-FINGER007:
●
Standard 26BIT Wiegand Format Proximity Readers
●
Standard 26BIT W 8BIT Burst Format Proximity and Keypad Reader
●
RF-TINY, RF10, RF20, RF30, RF70, RF500, RFK101
●
FGR006, FGR006EX, iP10, iP20, iP30, iPK101
●
FINGER007 Ver. A.0.0 or over (Wiegand Output Function).
Summary of Contents for Star Finger007
Page 1: ......
Page 7: ...p vii 16 Template 17 FCC REGISTRATION INFORMATION 18 RMA Request 95 95 96...
Page 49: ...Setting Changes 13 p 42...
Page 51: ...p 44 Setup Menu F1 1 Setup Menu F1...
Page 58: ...Setting Changes p 51 2 Setup Menu F2...
Page 59: ...p 52 Setup Menu F2...
Page 71: ...p 64 Setup Menu F3 3 Setup Menu F3...
Page 78: ...Setting Changes p 71 4 Setup Menu F4...
Page 79: ...p 72 Setup Menu F4...