p.59
[External Device]
●
An exit button error
●
Internal circuit element damaged or malfunctioning
Solution
Make sure of connection between the exit button and the 100R and of operation of exit but
ton.
☞ Check the connection between the exit button and the 100R.
Make sure to use a NO (Normal Open)-type exit button.
☞ Check the exit button operation.
1.
Check the condition of the connection cable (a short circuit or cut) between and the 10
0R.
2.
Connect two wires from the exit button.
I.
If the FACE007 operates when the exit button is pressed.
Replace the exit button.
II.
If the FACE007 does not respond.
Initialize the product.