System Wiring for Typical Application
p.16
●
Connect (+) wire of DC +12V power to Red wire.
●
Connect Power GND (-) wire of DC +12V to Black wire.
2
Door Lock Connection
Connection of POWER FAIL SAFE: Door Lock
●
Connect Door RELAY (COM), Grey with Red stripe wire to DC +12V (be sure that the exi
sting power supply has enough capacity to support this accessory or upgrade to a suffici
ent one.)
●
Connect (+) wire of Door Lock to Door RELAY (NC), Blue with White stripe wire.
●
Connect (-) wire of Door Lock to Power GND (-) wire.
Connection of POWER FAIL SECURE: Door Lock
●
Connect Door RELAY (COM), Grey with Red stripe wire to DC +12V (be sure that the exi
sting power supply has enough capacity to support this accessory or upgrade to a suffici
ent one.)
●
Connect (+) wire of Door Lock to Door RELAY (NO), White with Red stripe wire.
●
Connect (-) wire of Door Lock to Power GND (-) wire.
3
Alarm Device Connection
●
Connect Alarm RELAY (COM), White wire to DC +12V (be sure that the existing power
supply has enough capacity to support this accessory or upgrade to a sufficient one.)
●
Connect (+) wire of Alarm Device to Alarm RELAY (NO), Purple wire.
●
Connect (-) wire of Alarm Device to Power GND (-) wire.
4
Exit Button Connection
●
Connect one of the wires of Exit Button to Exit Button Input, Orange wire.
Summary of Contents for Star 100R
Page 1: ......
Page 14: ...Front Panel Description 5 p 8 ...
Page 15: ...Identifying Supplied Parts 6 p 9 Please unpack and check the contents of the box ...
Page 21: ...System Wiring for Typical Application 9 p 15 1 Power Connection ...
Page 29: ...p 23 Factory Defaulted Setting Values 16 Unlock followed by Door Contact Disable ...
Page 70: ...Template 16 p 64 ...