background image

p.2

Safety Information

5.

When installing the controller, fasten it securely and firmly. The fall of controller may

cause personal injury.

6.

Do not place conductive objects (e.g. screwdrivers, coins, metal parts, etc.) or

containers filled with water on top of the controller. Doing so may cause personal injury

due to fire, electric shock, or falling objects.

7.

Do not install the unit in humid, dusty, or sooty locations. Doing so may cause fire or

electric shock.

8.

If any unusual smells or smoke come from the unit, stop using the product. In such

case, immediately disconnect the power source and contact the service center.

Continued use in such a condition may cause fire or electric shock.

9.

If this product fails to operate normally, contact the nearest service center. Never

disassemble or modify this product in any way. (SAMSUNG is not liable for problems

caused by unauthorized modifications or attempted repair.)

10.

When cleaning, do not spray water directly onto parts of the product. Doing so may

cause fire or electric shock.

CAUTION

1.

Do not drop objects on the product or apply strong blows to it. Keep away from a

location subject to excessive vibration or magnetic interference.

2.

Do not install in a location subject to high temperature (over 50°C), low temperature

(below -30°C), or high humidity. Doing so may cause fire or electric shock.

3.

If you want to relocate the already installed product, be sure to turn off the power and

then move or reinstall it.

4.

Remove the power plug from the outlet when there is a lighting storm. Neglecting to

do so may cause fire or damage to the product.

5.

Keep out of direct sunlight and heat radiation sources. It may cause fire.

6.

Install it in a place with good ventilation.

7.

Avoid aiming the controller directly towards extremely bright objects such as sun.

8.

Apparatus shall not be exposed to dripping or splashing and no objects filled with

liquids, such as vases, shall be placed on the apparatus.

9.

The Mains plug is used as a disconnect device and shall stay readily operable at any

time.

Summary of Contents for SRK101V

Page 1: ...User Manual RFID Reader ...

Page 2: ...ction 1 Installation 2 Precautions on installation 2 1 If installing on a metal wall 2 2 If installing more than one reader side by side or front and back 3 External connection 3 1 Wiring Diagram 4 Initialization 1 Basic operations 1 1 Initial state when the power is supplied 1 2 Using the card 1 3 Using the keypad 1 4 LED Control 1 5 Buzzer Control 1 6 Tamper Control 5 Output format ii 1 3 4 4 5 ...

Page 3: ...put 2 1 Output waveform 2 2 Data type 3 8 bit burst output format 3 1 8 bit burst output format 6 Troubleshooting 1 Troubleshooting 7 Product specifications 1 Product specifications 8 RMA Request 9 Warranty Policy and Limitation of Liability Back cover 13 13 13 14 14 14 15 15 16 16 18 18 19 21 23 ...

Page 4: ...ompanying the appliance WARNING To reduce the risk of fire or electric shock do not expose this appliance to rain or moisture WARNING 1 Be sure to use only the standard adapter that is specified in the specification sheet Using any other adapter could cause fire electrical shock or damage to the product 2 Incorrectly connecting the power supply or replacing battery may cause explosion fire electri...

Page 5: ...hen cleaning do not spray water directly onto parts of the product Doing so may cause fire or electric shock CAUTION 1 Do not drop objects on the product or apply strong blows to it Keep away from a location subject to excessive vibration or magnetic interference 2 Do not install in a location subject to high temperature over 50 C low temperature below 30 C or high humidity Doing so may cause fire...

Page 6: ...safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with cart stand tripod bracket or table specified...

Page 7: ...h authentication of the presented proximity card and personal identifi cation number using the keypad With its red green and orange indicators as well as the Piezo buzzer this model is guaranteed to make a stable and correct operation 13 56 MHz MIFARE Contactless Smart Card PIN Reader Compatible with ISO14443 Type A 34 bit Wiegand RS 232 Data Output 8 Bit Burst Output Format supported Numeric keyp...

Page 8: ...ct introduction p 5 2 What s included Check if the following items are included in the product package 3 At a glance 3 1 Front Rear Figure 2 1 rf10structure 1 LED Displays the status of the system operation ...

Page 9: ... Port Purple TX_OUT RS 232 Output Terminal Not used Orange Not used Not used Brown Not used Not used Input Yellow Green LED control Green LED Control Input Terminal Gray Orange LED Control Orange LED Control Input Terminal Blue Buzzer Control BUZZER Control Input Port Tamper Pink Tamper COM COM Port of Tamper Switch Light yellow Tamper NC NC Port of Tamper Switch RS 232 GND Black GND GND 5 Cable s...

Page 10: ...nection 3 p 7 1 Installation 1 See Figure 1 to drill 6 32 holes and 1 2 holes totally 4 into the wall 2 Tighten the four screws to secure the product to the wall 3 With the provided 3mm hex wrench fix the outer case to the product ...

Page 11: ...tween the metal wall and the reader as shown below 2 2 If installing more than one reader side by side or front and back If you install more than one reader side by side or front and back the read range may be reduced In this case if you present a card to one reader the other reader may recognize the same card meaning both readers read the same card simultaneously To avoid this problem keep at lea...

Page 12: ...p 9 3 External connection 3 1 Wiring Diagram Item Cable Wiring Power Supply Unit Connect the DC 12V to the red line Connect GND to the black line Wiegand Connection Connect the green line of the product to the Wiegand D0 input port of the ...

Page 13: ...ontrol the red indicator See 1 4 LED Control Buzzer Control Enables you to turn on or off the buzzer To control the buzzer connect the blue line to the controller s output relay See 1 5 Buzzer Control RS 232 Connection Connect to the COM port of the PC Connect pin 2 of the DB 9 connector to the purple line connect the black of the device RS 232 GND to pin 5 of the DB 9 connector Tamper control Con...

Page 14: ...tor turns off and for receiving the next card the red indicator stays ON 1 3 Using the keypad Hold down the keypad until you hear a beep The reader transfers the keypad data to the controller As soon as you press the keypad the orange indicator turns on followed by the reader transferring the keypad data to the controller Then only the red indicator turns on 1 4 LED Control You can control both gr...

Page 15: ...e I O settings to set the buzzer control so that it sounds an additional beep for authorized or unauthorized access upon user authentication Furthermore you can make various modifi cations according to the different I O settings of the controller For more information about the I O settings of the controller refer to the user manual of the controller Card reading is not available while the buzzer c...

Page 16: ...Output format 5 p 13 1 WIEGAND output 1 1 Timing Diagram 1 2 Data Format 34 bit Bit 1 Even Parity bit 2 bit 17 Bit 2 Bit33 4 byte ID Number Bit 34 Odd Parity bit 18 bit 33 ...

Page 17: ...form 2 2 Data type START 0X02H DATA 10 Char END 0x03H LRC START 0X02H DATA 10 Char END 0x03H LRC Check the following settings Baud Rate 9600bps Data Bit 8 Parity Bit None Stop Bit 1 LRC This is the result of XOR operation of each byte from Start to End ...

Page 18: ...mat 3 1 8 bit burst output format Keypads Binary Hexa Keypads Binary Hexa 0 11110000 F0 6 10010110 96 1 11100001 E1 7 10000111 87 2 11010010 D2 8 01111000 78 3 11000011 C3 9 01101001 69 4 10110100 B4 ESC 01011010 5A 5 10100101 A5 ENT 01001011 4B ...

Page 19: ...on of the reader If you are using multiple readers that are connected to one adapter make sure that the adapter should be large enough to cover the current consumption multiplied by the reader count 2 Even with a large adapter enough to supply adequate power if the power cable is not a dedicated line such as communication line or UPT cable or if it s so long to cause power loss you d better replac...

Page 20: ...Troubleshooting p 17 2 If you encounter a different read range for each card that is made by the same manufacturer please contact the nearest customer service Problem Solution ...

Page 21: ...Output Port 34bit Wiegand 8bit Burst for PIN LED Indicator 3 LED Indicators Red Green and Orange Beeper Piezo Buzzer Keypad 12 Key Touch Keypad with Back Lighting Operating Temperature 25 C to 50 C Operating Humidity 10 to 90 relative humidity non condensing Color Material Silver with Black Polycarbonate Aluminum Die casting Dimension W x H x D mm 87 0 x 109 0 x 25 0 Weight 350g 10 ...