background image

p.3

IMPORTANT SAFETY INSTRUCTIONS

1

IMPORTANT SAFETY INSTRUCTIONS

1.

Read these instructions.

2.

Keep these instructions.

3.

Heed all warnings.

4.

Follow all instructions.

5.

Do not use this apparatus near water.

6.

Clean only with dry cloth.

7.

Do not block any ventilation openings. Install in accordance with the manufacturer’s ins

tructions.

8.

Do not install near any heat sources such as radiators, heat registers, or other apparatus

(including amplifiers) that produce heat.

9.

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized

plug has two blades with one wider than the other. A grounding type plug has two bla

des and a third grounding prong. The wide blade or the third prong is provided for you

r safety. If the provided plug does not fit into your outlet, consult an electrician for repla

cement of the obsolete outlet.

10.

Protect the power cord from being walked on or pinched particularly at plugs, convenie

nce receptacles, and the point where they exit from the apparatus.

11.

Only use attachments/accessories specified by the manufacturer.

12.

Use only with cart, stand, tripod, bracket, or table specified by the manufacturer, or sol

d with the apparatus.

13.

Unplug this apparatus when a card is used. Use caution when moving the cart/ apparat

us combination to avoid injury from tip-over.

14.

Refer all servicing to qualified service personnel. Servicing is required when the apparat

us has been damaged in any way, such as power supply cord or plug is damaged, liquid

has been spilled or objects have fallen into the apparatus, the apparatus has been expo

sed to rain or moisture, does not operate normally, or has been dropped.

Summary of Contents for iMDC-MAIN

Page 1: ......

Page 2: ......

Page 3: ...CRIPTION 4 2 iMDC MAIN OPERATING STATUS LED DESCRIPTION 4 3 Firmware Operating Status LED description 5 iMDC RIM BOARD 5 1 iMDC RIM Remote Interface Module Board Configuration iMDC RIM BOARD ARRANGEMENT AND DESCRIPTION 3 INSTALLATION TIPS CHECK POINTS 1 INSTALLATION CONFIGURATION 2 RECOMMENDED CABLE TYPE AND PERMISSIBLE LENGTH OF CABLE 3 CHECK POINT DURING INSTALLATION 3 1 REVERSE DIODE CONNECTION...

Page 4: ... READER LED BUZZER CONTROLLING IN POWER FAIL SECURE MODE Power Fail Secure Mode How to Indicate Door Opening Status Using LED of Reader in Power Fail Secure How to operate 9 4 READER LED BUZZER CONTROLLING IN POWER FAIL SAFE MODE Power Fail Safe Mode How to Indicate Door Opening Status Using LED of Reader in Power Fail Safe How to operate 6 NETWORK SETTING 1 PRIVATE IP NETWORK SETTING 1 1 CORRECT ...

Page 5: ...G 6 1 iMDC RIM NETWORK SETTING 6 2 iMDC RIM TEST 8 OPERATIONS 1 NORMAL OPERATION 2 INITIAL SETTING VALUE 9 Troubleshooting 10 APPENDIX 1 Default value of iMDC RIM 1 1 Reader 1 2 Input 1 3 Output 2 Event Output Number 32Door RIM 12EA 11 SPECIFICATION 1 iMDC MAIN Specification 2 iMDC RIM Specification 3 DIODE SPECIFICATION 12 FCC REGISTRATION INFORMATION 13 RMA Request 40 40 43 47 47 48 49 50 51 51 ...

Page 6: ......

Page 7: ...he user to the presence of importa nt operating and maintenance servicing instructions in the literature accompanying the ap pliance WARNING To reduce the risk of fire or electric shock do not expose this appliance to rain or moisture WARNING 1 Be sure to use only the standard adapter that is specified in the specification sheet Usin g any other adapter could cause fire electrical shock or damage ...

Page 8: ...t in any way SAMSUNG is not liable for problems caused by unauthorized modifications or attempted repair 10 When cleaning do not spray water directly onto parts of the product Doing so may ca use fire or electric shock CAUTION 1 Do not drop objects on the product or apply strong blows to it Keep away from a locat ion subject to excessive vibration or magnetic interference 2 Do not install in a loc...

Page 9: ...u r safety If the provided plug does not fit into your outlet consult an electrician for repla cement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenie nce receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with cart stand tripod bracket or table spe...

Page 10: ......

Page 11: ...d wit h various devices such as Exit Buttons Door Contact Sensors PIR Sensors Window Br eakage Sensors and Fire Sensors to strengthen security iMDC consists of iMDC MAIN and iMDC RIM between these are connected by Ether net communication And iMDC MAIN can establish the independent or multiple netw ork connection via network communication All system setting such as user card registration input outp...

Page 12: ...ss is denied After s pecific time Anti Pass back error is released and access is allowed USER EXPIRATION READER SETTING The reader set this function makes the card expiration automatically when the card is recognized on the reader When expired cards by this function are read by the reader connected from iMDC th e card can t gain access anymore and the validity expiration event is generated WIEGAND...

Page 13: ...et up time range is granted and the access that occurs out of set up time range is denied and time schedule er ror is recorded Reader time schedule If reader mode is set to RF PW mode only RF card is need ed to gain an access in the time schedule range and RF PW is needed to gain an a ccess out of the time schedule range Input time schedule You can input time schedule code you want to use to each ...

Page 14: ...ower Fail Safe mode The door is opened when the emergency occurs Power Fail Secure mode The door is closed when the emergency occurs DOOR OPEN TIMEOUT ALARM FORCED DOOR OPEN ALARM The Door Open Timeout Alarm function is to notice the administrator that any case of the door opening even after the normal opening time and waiting time The Door Open by Force Alarm function is to activate the alarm whe...

Page 15: ... can open and close the grouped door absence mana gement section If the door group is closed by Absent Management function people can t open any door in absence management section After the authorized manager r evoke the absence management the door can be opened again REDUNDANCY FUNCTION You can install sub iMDC MAIN for redundancy If communication between main iM DC MAIN and iMDC RIM is disconnec...

Page 16: ... Card PW Both RF card and password are necessary to grant access DATA AND EVENT UP DOWNLOAD User data event information and setting values are downloaded uploaded from to t he host computer by application software STARWATCH ENTERPRISE DOOR SETTING iMDC offers interfaces of 32 RF readers therefore the number of controlled doors ca n be up to 32ea In this case exit button must be used to exit from i...

Page 17: ...p 11 IDENTIFYING SUPPLIED PARTS 2 IDENTIFYING SUPPLIED PARTS Please unpack and check the contents of the box 2 1 Supplied Parts in iMDC MAIN Gift Box 2 2 Supplied Parts in iMDC RIM Gift Box ...

Page 18: ...iMDC INSTRUCTION p 12 3 DIMENSION 4 iMDC MAIN BOARD ...

Page 19: ...g status of enclosur e 7 Communicatio n Status LED C onnector It s the connector to be connected to enclosure using cable Green LED indicates status of Ethernet communication 8 Communicatio n Status LED C onnector It s the connector to be connected to enclosure using cable Yello w LED indicates status of Ethernet communication 9 Power Status L ED Connector It s the connector to be connected to enc...

Page 20: ...ode Normal St atus Description D1 Communic ation Stat us LED betwe en iMDC MAIN and Host PC FLICKER It s the LED to indicate communication status between iMDC MAIN and Host PC The LED flickers when communication bet ween iMDC MAIN and PC is processed D4 Reader Da ta Process Status LED FLICKER It s the LED to indicate reader data process status The LED flic kers when reader data transmitted from iM...

Page 21: ...LICKER It s the LED to indicate iMDC MAIN function setting is possible by STARWATCH ENTERPRISE D9 Event Savi ng Status LED FLICKER It s the LED to indicate event saving status happened in iMDC MAIN D10 iMDC MAI N Operati ng status LED FLICKER It s the LED to indicate iMDC MAIN function operating status LED Code Normal St atus Description 5 iMDC RIM BOARD 5 1 iMDC RIM Remote Interface Module Board ...

Page 22: ...osure using screws 2 Reader 1 Port It s the reader port to process Wiegand Reader Input 3 Reader 2 Port It s the reader port to process Wiegand Reader Input 4 Relay Output 1 Port It s the ports for FORM C COM NO NC Relay Output 5 Relay Output 2 Port 6 Relay Output 3 Port 7 Relay Output 4 Port 8 Relay Output 5 Port 9 Relay Output 6 Port ...

Page 23: ...hernet connection port to perform communication betw een iMDC MAIN and Host PC iMDC MAIN and the other iMDC M AINs iMDC MAIN and iMDC RIM 23 Power Status L ED Connector It s the connector to be connected to enclosure using cable If red LED is turned on it means power has properly supplied 24 Communicatio n Status LED Connector It s the connector to be connected to enclosure using cable Green LED i...

Page 24: ...iMDC INSTRUCTION p 18 tains even after reset 27 Status LED It s the LED to indicate iMDC RIM s status The LED turns off durin g normal status No Code Description ...

Page 25: ...INSTALLATION TIPS CHECK POINTS 3 p 19 1 INSTALLATION CONFIGURATION The system installation cables should be connected as follows ...

Page 26: ... conductor shielded 300m Belden 9514 22 AWG 8 conductor shielded 4 Door Lock Alarm Device Lock Alarm iMDC RIM Belden 9409 18AWG 2 conductor unshielded 300m 5 iMDC Cable iMDC RIM Cable iMDC MAIN iMDC MAIN iMDC MAIN iMDC RIM iMDC MAIN Host P C UTP Cable CAT5 Catagory5 100m 150m 3 CHECK POINT DURING INSTALLATION 3 1 REVERSE DIODE CONNECTION If you connect an inductor Door Locks or Alarm device to the...

Page 27: ...o add a reverse diode between the inductor coils to a bsorb this surge voltage If you do not connect a reverse diode the surge voltage will transfer and damage the electronic circuit of the controller 1N4004 1N4007 or equality efficiency diode is included in gift box ...

Page 28: ......

Page 29: ... an 8 channel DIP switch on the right middle of the iMDC MAIN for Board ID setting Each channel of DIP switch has assigned address values and the Board ID is the sum value of each switch set to ON position Refer to the example below Board ID must be set before main power connection to the iMDC MAIN If more than one iMDC MAIN boards are installing you must set different Board ID for each iMDC MAIN ...

Page 30: ... 6 7 8 Board ID Setting Status OFF OFF OFF OFF OFF OFF OFF OFF 0 ON OFF OFF OFF OFF OFF OFF OFF 1 OFF ON OFF OFF OFF OFF OFF OFF 2 ON ON OFF OFF OFF OFF OFF OFF 3 OFF OFF ON ON ON ON ON ON 253 OFF ON ON ON ON ON ON ON 254 ON ON ON ON ON ON ON ON 255 ...

Page 31: ...wer switched on to the iMDC RIM Wiring aft er main power switched on may cause electrical shock 1 iMDC WIRING CONFIGURATION The figure below is basic installation configuration for iMDC MAIN and iMDC RIM Wire iM DC as the configuration below No Code ...

Page 32: ...p 26 1 PC for installing application software STARWATCH ENTERPRISE 2 iMDC MAIN 3 iMDC RIM 4 HUB 5 Reader 6 Door Lock 7 Door Contact 8 Exit Button 9 Power No Code 2 WIRING PARTS CODE 2 1 IMDC MAIN 2 2 IMDC RIM ...

Page 33: ...D EARTH GROUND wiring equalizes all ground level to zer o and protects from the thunderbolt or surge voltage 4 iMDC MAIN POWER WIRING Confirm that main power switched OFF before wiring Connect 12V red wire of DC12V power supply to Power terminal block 12V of iM DC MAIN Connect GND black wire of DC12V power supply to Power terminal block GND of iMDC MAIN ...

Page 34: ...al block 12V of iM DC RIM Connect GND black wire of DC12V power supply to Power terminal block GND of iM DC RIM 6 NETWORK CABLE WIRING BETWEEN iMDC MAIN AN D iMDC RIM 6 1 WIRING WHEN PORTS ARE ENOUGH TO CONNECT NETWORK DEVICE Follow below the Figure solution 1 for wiring if there are enough TCP IP ports to connect network devices hub router etc ...

Page 35: ... CONNECT TO NETWORK DEVI CE If there are not enough TCP IP ports to connect network devices hub router etc configur e equality network using by cross cable and then follow the Figure Solution 2 Please refe r to 6 Network setting for more information about IP setting between iMDC MAIN and iMD C RIM ...

Page 36: ...lock D0 of iMDC R IM Connect DATA1 white wire of RF reader to Reader Port terminal block D1 of iMDC RI M You can use external 12V DC power source for RF reader But in this case you sh ould connect GND of external power source to GND Reader Port terminal block of iMDC RIM If you do not connect GND of external power source to iMDC RIM Wiegand data can t be transferred to iMDC RIM due to the voltage ...

Page 37: ...C RIM 9 OUTPUT WIRING Connect Door Lock and Alarm Device to Output Port terminal block Relay outputs of iMDC RIM as follow 9 1 DOOR LOCK WIRING IN CASE OF POWER FAIL SAFE DOOR LOCK Connect 12V wire of DC12V power supply to Output Port terminal block RCOM1 of i MDC RIM Connect wire of Door Lock to Output Port terminal block RNC1 of iMDC RIM Connect wire of Door Lock to GND wire of DC12V power suppl...

Page 38: ...to Output Port terminal block RNO1 of iMDC RIM Connect wire of Door Lock to GND wire of DC12V power supply Must connect reverse diode between wire and wire of Door Lock IMPORTANT 9 2 ALARM DEVICE WIRING Connect 12V wire of DC12V power supply to Output Port terminal block RCOM2 of i MDC RIM Connect wire of Alarm Device to Output Port terminal block RNO2 of iMDC RIM ...

Page 39: ...l Secure Mode In this mode if power is failed or emergencies occur the door is closed automatically In this mode security level can be higher because all of the doors are closed automatically b ut people inside may not exit How to Indicate Door Opening Status Using LED of Reader in Power Fail Secure If you connect the LED control wire of the reader to Relay output connected with door lock Door loc...

Page 40: ...DE Power Fail Safe Mode In this mode if power is failed or emergencies occurs the door is opened automatically In this mode security level can be lowered because all of the doors are opened automaticall y but people inside can exit How to Indicate Door Opening Status Using LED of Reader in Power Fail Safe If you connect the LED control wire of the reader to Relay output connected with door lock Do...

Page 41: ...der is being connected to reader 1 and then if LED control wire is connected as figure above LED color is changed from Green to Red If you are using separate power sources for the iMDC and the Door Lock it is reco mmended to ground each power source properly ...

Page 42: ......

Page 43: ...ivate ID The configuration is the most stable netw ork system for IMDC MAIN and IMDC RIM It is advised to build up private LAN network for I MDC MAIN and IMDC RIM The IP is searched and set automatically using STARWATCH ENTERPRISE or iMDC EMULATO R Refer to 6 Network setting and 7 iMDC EMULATOR ...

Page 44: ...68 10 9 9 6005 RIM3 192 168 10 1 3 255 255 255 0 192 168 10 1 192 168 10 2 192 168 10 9 9 6005 RIM4 192 168 10 1 4 255 255 255 0 192 168 10 1 192 168 10 2 192 168 10 9 9 6005 RIM5 192 168 10 1 5 255 255 255 0 192 168 10 1 192 168 10 2 192 168 10 9 9 6005 RIM6 192 168 10 1 6 255 255 255 0 192 168 10 1 192 168 10 2 192 168 10 9 9 6005 RIM7 192 168 10 1 7 255 255 255 0 192 168 10 1 192 168 10 2 192 1...

Page 45: ...8 10 2 192 168 10 9 9 6005 RIM16 192 168 10 2 6 255 255 255 0 192 168 10 1 192 168 10 2 192 168 10 9 9 6005 NO iMDC RIM IP Subnetmask Gateway DNS iMDC MAIN IP Address iMDC MAIN Port Numbe r 1 2 WRONG PRIVATE IP SETTING EXAMPLE When Using C Class Subnetmask 255 255 255 0 iMDC MAIN IP 192 168 10 10 iMDC RIM 1 192 168 11 30 iMDC RIM 2 192 168 11 31 When Using B Class Subnetmask 255 255 0 0 iMDC MAIN ...

Page 46: ...to search the information of the iMDC M AIN iMDC RIM board by manual searching function If firewall of PC blocks the port used for iMDC MAIN and iMDC RIM iMDC MAIN iMDC RI M communication server Set the firewall cancellation about the ports Otherwise the firew all may block the applicable ports used to communicate with STARWATCH ENTERPRISE 2 1 iMDC MAIN IP ADDRESS SETTING STARTWATCH ENTERPRISE pro...

Page 47: ...isted sites double clik the registered site 3 To register new site click the Site Setting button Input the Site Name where you want to install the device Input the IP adress of your PC that has installed communication ser ver for Communication Server IP For example if your IP adress is 192 168 52 10 input 192 168 52 10 for Communication Server IP Input the 51008 defualt values for Port Number ...

Page 48: ...he applicable iMDC MAIN board Click the Auto Search iMDC Controller button then a ll of the iMDC MAINs connected on the same network is searched Select the iMDC M AIN you want to register and move down with drag and drop Refer to the table below for appropriate setting Column Name Description Loop Name Insert loop name Loop Name should not be duplicated Device Name Insert device name Device Name s...

Page 49: ...er to Peer Port Insert port number to connect iMDC MAIN Default is 6002 Column Name Description 6 After iMDC MAIN setting is finished check all of settings in the first column then click th e iMDC Network Setting button to transmit input information to iMDC Main 3 iMDC RIM IP ADDRESS SETTING 1 It s iMDC RIM board network information setting All iMDC RIMs are searched on the s ame network and then ...

Page 50: ...MDC RIM Board and iMDC MAIN Default i s 6005 2 After each iMDC RIM setting is completed check all of settings in the first column Clic k RIM Network Setting button to link up with iMDC RIM board and then click the Next button 3 The step for Biometric Setting In this step you can only search LX006 and LX006SR fing erprint reader If you need to set other fingerprint device you need to go Loop and De...

Page 51: ...p 45 iMDC RIM IP ADDRESS SETTING 4 Check previous steps for iMDC MAIN and iMDC RIM board setting have completed pro perly and click the Save button to finish setting ...

Page 52: ......

Page 53: ...EMULATOR is made to basically test the network setting of iMDC MAIN and iMDC RI M Refer to the description below for the setting 1 ENVIROMENT SETTING 1 ENVIROMENT SETTING is to set the communication port between iMDC MAIN iMDC R ...

Page 54: ...ommunication between iMDC MAIN and iMDC RIM Default value is 6005 2 Save Communication port This button is used to save changed values of iMDC MAIN and iMDC RIM Receive Port Using default port value is recommended 2 FIRMWARE DOWLOAD 1 Select the device to transmit firmware Select one between iMDC MAIN and iMDC RIM Input IP and port of the device to transmit firmware in Device IP and Device Port Co...

Page 55: ...to open window to transmit firmware 3 Select the firmware you want to update 4 Start Transmission This button is to send firmware to the device iMDC MAIN or i MDC RIM If you stop in the middle of transmitting process you should restart from 2 step 5 If you want to stop transmitting click the Stop Transmission button Even though t ransmitting is stopped any problem doesn t occur 3 iMDC SEARCH 1 Sea...

Page 56: ...and then click the Download Information button to complete this process 4 RIM SEARCH 1 Search RIM This button is to search all existing iMDC RIM network information on the same network Searched iMDC RIM s MAC Address is displayed on the iMDC RIM LI ST 2 Double click iMDC RIM s MAC address you want to confirm or change 3 Download Information This button is to change the network information of the i...

Page 57: ... iMDC MAIN s IP address Default value is 192 168 1 99 iMDC Port It s the port for communication between iMDC MAIN and STARTWATCH ENTERPRISE Using def ault value 6001 is recommended for stable com munication 2 Start Polling This button is to displays the information of polling status 3 If the Polling ACK message appears it means polling function is normally operating 4 Stop Polling If you want to s...

Page 58: ... is displayed as iMDC Mac Address It s the Mac address for Ethernet Card Communication ID It s the address for communication iMDC MAIN IP It s searched iMDC MAIN board IP address iMDC MAIN G W It s searched gateway address of iMDC MAIN board iMDC MAIN DNS It s searched DNS address of iMDC MAIN board Server IP It s PC s IP address which installed communication server Server Port It s the PC s port ...

Page 59: ... network informati on The difference between RIM SEARCH and RIM SETTING is that RIM SETTING is able to select specific iMDC RIM you want to use 1 Input the iMDC RIM s IP address and port you want to use 2 Update Information This button is to search iMDC RIM s network information 3 Searched iMDC RIM s network information is displayed iMDC INFOMATION Description Firmware Version It shows the version...

Page 60: ...MAIN Usi ng default 6005 is recommended iMDC MAIN IP It s IP address of iMDC MAIN to connect iMDC RIM board iMDC INFOMATION Description 4 If you want to change the iMDC RIM s network setting change the network setting in i MDC RIM INFORMATION and click the Download Information button to complete 6 2 iMDC RIM TEST 1 Input the iMDC RIM IP address and port you want to search 2 Change Test Mode This b...

Page 61: ... 5 It indicates that 8 input of iMDC RIM is generated Status of input is displayed as ON a nd OFF 6 If you click Output test button 8 relay outputs of iMDC RIM are generated for 3 secon ds 7 After test is finished click the iMDC RIM Reboot button to initialize iMDC RIM ...

Page 62: ......

Page 63: ... efaults with the applicable LED on Exit Button To go out of inside press an exit button or present a registered card on the external re ader In this case the Door Relay 1 is opened for 3 seconds Defaults with the app licable LED on Alarms When an unregistered card is read or wrong password is input the access is denied a nd the alarm Relay 2 is activated for 3 seconds Defaults with the applicable...

Page 64: ...e iMDC first time or you initialize the iMDC the controller will set up all values to the default settings Factory Settings You can change the settings for desired app lication environment Please refer to the 10 APPENDIX section for the default setting value s ...

Page 65: ...is n ot enough iMDC MAIN recognizes that the communication between iMD C MAIN and iMDC RIM is disconnected iMDC RIM operates Power Fail Saf e mode and all doors are opened In this case after device setting is finished using STARTWATCH ENTERPRIS E reboot iMDC MAIN and iMDC RIM Then iMDC MAIN recognizes that t he communication is connected and operated normally 2 If it occurs during normal operation...

Page 66: ...n MS D OS window is displayed as below Ping test of iMDC MAIN or iMDC RIM installed by users is progressed in M S DOS window If It s normal status the message below is displayed If network condition is not stable or network is set wrongly fail message w ill be displayed as below ...

Page 67: ...on is not operated In this case set two men operation function to th e applicable reader The reader seems to read cards but iMDC does not respond or does not respond properly such a s displaying wrong card numbers Reason It may be caused from reader defect wiring error between the reader and the iMDC or the electric noises around Solution 1 Check that the power is supplied to the reader confirms t...

Page 68: ...st using IP address of iMDC MAIN and iMDC RIM 5 When noises are shown on the signals it is recommended to use shield ed wires and the unused wires to the common ground You can use repea ters also 6 Check the maximum cable length 150m ...

Page 69: ...APPENDIX 10 p 63 1 Default value of iMDC RIM Index No 1 2 3 4 5 6 7 8 READER R1 R2 INPUT B D S S S S S S OUTPUT L A E A A A A A 1 1 Reader R Reader 1 2 Input B Exit Button D Door Contact S Sensor ...

Page 70: ... 10 11 3 5 3 17 18 19 17 18 19 3 6 3 17 18 19 17 18 19 4 7 4 25 26 27 25 26 27 4 8 4 25 26 27 25 26 27 5 9 5 33 34 35 33 34 35 5 10 5 33 34 35 33 34 35 6 11 6 41 42 43 42 43 44 6 12 6 41 42 43 42 43 44 7 13 7 49 50 51 49 50 51 7 14 7 49 50 51 49 50 51 8 15 8 57 58 59 57 58 59 8 16 8 57 58 59 57 58 59 9 17 9 65 66 67 65 66 67 9 18 9 65 66 67 65 66 67 10 19 10 73 74 75 73 74 75 10 20 10 73 74 75 73 ...

Page 71: ... 113 114 115 15 30 15 113 114 115 113 114 115 16 31 16 121 122 123 121 122 123 16 32 16 121 122 123 121 122 123 Default value of output time is 3 seconds DOOR LOCK DOOR LOCK output number when access is granted ALARM ALARM output number when alarm events occur ETC Output number about other events Ex If a card is presented to reader 1 1 iMDC RIM board output is activated If t he error occurs output...

Page 72: ......

Page 73: ...0 Users Event Buffer 200 000 Event Buffer Power Current DC 12V Max 700mA Communication Ethernet Communication Ethernet 10 100 Mbps Interface Maximum 16 iMDC RIMs can be connected One iMDC RIM can b e connected with 2 readers 8 In Output Processes Maximum 32 readers 26Bit Wiegand 4 8bit Burst 34Bit Wiegand 4 8bit Burst Processes Maximum 128 Input Available to set input format Processes Maximum 128 ...

Page 74: ...ro Processor Power Current DC 12V Max 350mA Memory Internal Memory 128 Kbyte Flash Memory External Memory 4K SRAM Reader 2ea Input Port 8ea Available to set input format Output Port 8ea 2 FORM C Relay Output COM NO NC DC 12V 18V Rating Max 2A Ethernet Speed 10 100 Mbps LED Indicator Status LED indicator Operating Temperature 0 65C 32 149F Operating Humidity 10 90 Relative humidity non condensing D...

Page 75: ...p 69 DIODE SPECIFICATION 3 DIODE SPECIFICATION Model 1N4007 Power Current 50 1000 V Min 1 0 A ...

Page 76: ......

Page 77: ...e received including interference that may caus e undesired operation This equipment has been tested and found to comply with the limits for a Class A Digital De vice pursuant to Part 15 of the FCC rules These limits are designed to this equipment gener ates uses and can radiate radio frequency energy and if not installed and used in accordan ce with the instructions may cause harmful interference...

Page 78: ......

Page 79: ...g Gangseo Gu Seoul 157 030 Korea Tel 82 2 2659 0055 Fax 82 2 2659 0086 E mail webmaster idteck com Website www idteck com E Training Center http www idtecktraining com IDTECK Production Facility and RMA Center 2F 89 4Dodang Dong Weonmi Gu Bucheon Si Gyeonggi Do 420 130 Korea Tel 82 2 2659 0055 Fax 82 2 2659 0086 E mail webmaster idteck com Website www idteck com E Training Center http www idtecktr...

Reviews: