![IDTECH Vivopay Neo 2 Developer'S Manual Download Page 331](http://html.mh-extra.com/html/idtech/vivopay-neo-2/vivopay-neo-2_developers-manual_618786331.webp)
NEO 2 Interface Developer’s Guide
Copyright © 2019, International Technologies & Systems Corporation. All rights reserved.
331
Data Objects
Data Item
Length (bytes)
Description
Mode
1
-0x00: disable;
-0x01: enable;
Response Frame
Byte 0-9
Byte 10
Byte 11
Byte 12
Byte 13
Byte 14
Byte 15
Header Tag &
Protocol Version
Command
Status Code
Data Length
(MSB)
Data Length
(LSB)
CRC (MSB) CRC (LSB)
ViVOtech2\0
4Ch
See
00h
00h
8.21.5.
Save/Delete Log (4C-05)
Use this command to save the log from ring buffer to a file or delete the current log file.
Command Frame
Byte 0-9
Byte 10
Byte 11
Byte 12
Byte 13
Byte 14
Byte 15
Byte 16
Header Tag &
Protocol
Version
Command
Sub-
Command
Data
Length
(MSB)
Data
Length
(LSB)
Data
CRC
(MSB)
CRC (LSB)
ViVOtech2\0
4Ch
05h
00h
01h
Data Objects
Data Objects
Data Item
Length (bytes)
Description
Mode
1
-0x00: Delete;
-0x01: Save;
Response Frame
Byte 0-9
Byte 10
Byte 11
Byte 12
Byte 13
Byte 14
Byte 15
Header Tag &
Protocol
Version
Command Status Code
Data Length
(MSB)
Data Length
(LSB)
CRC (MSB)
CRC (LSB)
ViVOtech2\0
4Ch
See
00h
00h