12. Serial RapidIO Registers > SerDes Per Lane Register
408
Tsi578 User Manual
June 6, 2016
Integrated Device Technology
www.idt.com
12.14.6
SerDes Lane
1 Pattern Matcher Control Register
This register contains the controls the Pattern Matcher and the error counters associated with the
corresponding matcher in each lane.
Register name: SMAC{0,2,4,6,8,10,12,14}_PM_CTL_1
Reset value: 0x0000_0000
Register offset: 1E070, 1E270, 1E470, 1E670, 1E870,
1EA70, 1EC70, 1EE70
Bits
0
1
2
3
4
5
6
7
00:07
OV14
COUNT
08:15
COUNT
16:23
Reserved
24:31
Reserved
SYNC
MODE
Bits
Name
Description
Type
Reset
Value
0
OV14
1= multiply COUNT by 128. When OV14=1 and count = 2
15
-1, signal
overflows
Note: Read operations on this register is pipelined. Two reads needed
to get current value. The values are volatile and the value may change
at any time
R/W
0x0
1:15
COUNT
Current error count
If OV14 field is active, multiply count by 128.
Note: Read operation on this register is pipelined. Two reads needed to
get “current” value. The values are volatile (that is, value may change at
any time)
R/W
0x0
16:27
Reserved
NA
R
0x0
28
SYNC
Synchronize pattern matcher LFSR with incoming data.
Must be turned on then off to enable checking.
RX_ALIGN_EN must be disabled when checking PRBS patterns
Note: This bit returns to its reset value on reset
R/W
0x0
29:31
MODE
Pattern to match
0 = Disabled
1 = lfsr15
2 = lfsr7
3 = d[n] = d[n-10]
4 = d[n] = !d[n-10]
5:7 = Reserved
Note: This field returns to its reset value on reset
R/W
0x0