6. Event Management > Event Notification
CPS-1848 User Manual
140
June 2, 2014
Formal Status
This document is confidential and is subject to an NDA.
Integrated Device Technology
Table 53: Physical Layer Event Notification Control
Event
Standard Port-Write Reporting
Interrupt Reporting
Error Log Reporting
Control symbol CRC error
Port {0..17} Error Report Enable
Register
.CS_CRC_ERR_EN = 1
and
Port {0..17} Operations
Register
.PORT_PW_EN = 1
Port {0..17} Error Report Enable
Register
.CS_CRC_ERR_EN = 1
and
Port {0..17} Operations
Register
.PORT_INT_EN = 1
Port {0..17} Error Report Enable
Register
.CS_CRC_ERR_EN = 1
and
Port {0..17} Operations
Register
.PORT_LOG_EN = 1
Received an acknowledgement
control symbol with unexpected
ackID
Port {0..17} Error Report Enable
Register
. UNEXP_ACKID_EN =
1 and
Port {0..17} Operations
Register
.PORT_PW_EN = 1
Port {0..17} Error Report Enable
Register
. UNEXP_ACKID_EN =
1 and
Port {0..17} Operations
Register
.PORT_INT_EN = 1
Port {0..17} Error Report Enable
Register
. UNEXP_ACKID_EN =
1 and
Port {0..17} Operations
Register
.PORT_LOG_EN = 1
Received a packet not accepted
control symbol
Port {0..17} Error Report Enable
Register
.CS_NOT_ACC_EN = 1
and
Port {0..17} Operations
Register
.PORT_PW_EN = 1
Port {0..17} Error Report Enable
Register
.CS_NOT_ACC_EN = 1
and
Port {0..17} Operations
Register
.PORT_INT_EN = 1
Port {0..17} Error Report Enable
Register
.CS_NOT_ACC_EN = 1
and
Port {0..17} Operations
Register
.PORT_LOG_EN = 1
Received a packet with a bad
ackID
Port {0..17} Error Report Enable
Register
.PKT_ILL_ACKID_EN =
1 and
Port {0..17} Operations
Register
.PORT_PW_EN = 1
Port {0..17} Error Report Enable
Register
1 and
Port {0..17} Operations
Register
.PORT_INT_EN = 1
Port {0..17} Error Report Enable
Register
.PKT_ILL_ACKID_EN =
1 and
Port {0..17} Operations
Register
.PORT_LOG_EN = 1
Received a packet with bad CRC
Port {0..17} Error Report Enable
Register
.PKT_CRC_ERR_EN =
1 and
Port {0..17} Operations
Register
.PORT_PW_EN = 1
Port {0..17} Error Report Enable
Register
.PKT_CRC_ERR_EN =
1 and
Port {0..17} Operations
Register
.PORT_INT_EN = 1
Port {0..17} Error Report Enable
Register
.PKT_CRC_ERR_EN =
1 and
Port {0..17} Operations
Register
.PORT_LOG_EN = 1
Received a packet that exceeds
276 bytes
Port {0..17} Error Report Enable
Register
.PKT_ILL_SIZE_EN = 1
and
Port {0..17} Operations
Register
.PORT_PW_EN = 1
Port {0..17} Error Report Enable
Register
and
Port {0..17} Operations
Register
.PORT_INT_EN = 1
Port {0..17} Error Report Enable
Register
.PKT_ILL_SIZE_EN = 1
and
Port {0..17} Operations
Register
.PORT_LOG_EN = 1
Received a data character in
IDLE1
Port {0..17} Error Report Enable
Register
.IDLE1_ERR_EN = 1
and
Port {0..17} Operations
Register
.PORT_PW_EN = 1
Port {0..17} Error Report Enable
Register
.IDLE1_ERR_EN = 1
and
Port {0..17} Operations
Register
.PORT_INT_EN = 1
Port {0..17} Error Report Enable
Register
.IDLE1_ERR_EN = 1
and
Port {0..17} Operations
Register
.PORT_LOG_EN = 1
Non-outstanding ackID in
Link-Response
Port {0..17} Error Report Enable
Register
.LR_ACKID_ILL_EN = 1
and
Port {0..17} Operations
Register
.PORT_PW_EN = 1
Port {0..17} Error Report Enable
Register
and
Port {0..17} Operations
Register
.PORT_INT_EN = 1
Port {0..17} Error Report Enable
Register
.LR_ACKID_ILL_EN = 1
and
Port {0..17} Operations
Register
.PORT_LOG_EN = 1