background image

 

 

IDS HYYP 

Installation Checklist 

1.

 

HYYP Installation Checklist 

1.1.

 

Firmware Version 

Check the firmware version of the IDS X-Series panel by holding down the * key 

until it beeps, then press the * key again. 

 

 

 

For the HYYP App to work the IDS X-Series panel must be version 2.52 or higher. 

 

1.2.

 

X-Series Wiring 

Connect the provided serial cable from the serial connector on the X-series panel to the serial 

connector on the HYYP Hub. 

 

Tip: The red wire on the X-Series panel should be closest to the panel’s heat sink.

 

1.3.

 

X-Series Programming 

All required programming is done in installer programming. 

 

 

Enter Installer Code [9][9][9][9][*] 

 

Go to location 196 [1][9][6][*] 

 

Enter any six digit code [1][2][3][4][5][6][*] 

(This is to authorise the HYYP serial connection) 

 

Go to location 61 [6][1][*] 

(This is the partition’s account code: 61 – Partition 1; 62 – Partition 

2; 63 – Partition 3…)

 

 

Enter the account code issued by the control room [1][2][3][4][*] 

 

Exit installer programming [#] 

 

 

Summary of Contents for HYYP

Page 1: ...r on the X series panel to the serial connector on the HYYP Hub Tip The red wire on the X Series panel should be closest to the panel s heat sink 1 3 X Series Programming All required programming is d...

Page 2: ...a valid clock pulse from the IDS805 alarm panel The serial connection between the HYYP Hub and the IDS 805 Key bus Interface is shown in the image above 1 5 Interface Board Jumpers The interface board...

Page 3: ...Server Auth LEDs will flash together and once it has made a successful connection to the HYYP platform the Server Auth LED will stay on and the Network Comms LED will flash when it s communicating on...

Page 4: ...install the HYYP Home App go to the Google Play Store and search for HYYPHome And click install Once installed open the HYYPHome App the first time you open the app you will be asked to sign up or lo...

Page 5: ...if you have a HYYP Hub to connect Click I have a new HYYP Hub Give your HYYP Hub a name and choose a site colour The site colour will help distinguish between multiple sites Click Next Enter the HYYP...

Page 6: ...hen using the IP Connect you must go back to location 196 and enter when asked to press sync button Fill in details of where the HYYP Hub is installed Click Next Your HYYP Hub has successfully been sy...

Page 7: ...n is 2 52 or higher and that there are no blank zone names 3 3 Error 207 Error 207 indicates the commands time stamp is outdated This could be due to the network delaying the message 3 4 Error 208 Err...

Reviews: