IDS HYYP
Installation Checklist
1.
HYYP Installation Checklist
1.1.
Firmware Version
Check the firmware version of the IDS X-Series panel by holding down the * key
until it beeps, then press the * key again.
For the HYYP App to work the IDS X-Series panel must be version 2.52 or higher.
1.2.
X-Series Wiring
Connect the provided serial cable from the serial connector on the X-series panel to the serial
connector on the HYYP Hub.
Tip: The red wire on the X-Series panel should be closest to the panel’s heat sink.
1.3.
X-Series Programming
All required programming is done in installer programming.
Enter Installer Code [9][9][9][9][*]
Go to location 196 [1][9][6][*]
Enter any six digit code [1][2][3][4][5][6][*]
(This is to authorise the HYYP serial connection)
Go to location 61 [6][1][*]
(This is the partition’s account code: 61 – Partition 1; 62 – Partition
2; 63 – Partition 3…)
Enter the account code issued by the control room [1][2][3][4][*]
Exit installer programming [#]