VAC-5000HD User Guide
22
8.2 Setting input and output (Setting menu)
8.2.1 [F01 to F03] Copying EDID
Note
:
“[ ]” shows each menu number in this chapter.
EDID of sink devices can be read and saved, and three EDID can be registered in the VAC as same as
internal EDID.
(1) Select the sink device whose EDID will be copied and press the “SET” key to register it.
Menu number: [F01 to F03]
(2) Select the copy data you want to use.
Menu number: [F14]
(3) Select “02” for the EDID setting.
Menu number: [F10]
to
OUT 1
OUT 5
LC monitor
Copied data 1
Copied data 2
Copied data 3
Copied EDID
EXTERNAL EDID
Internal EDID
Blu-ray player
Step 1
Step 2
Step 3
[Fig. 8.1] Copying and saving EDID
Menu numbers
F01 to F03: Copied data 1 to 3
Setting values
01 to 05: OUT1 to OUT5
[Default: OUT1]
Note:
If cascade connection is employed, the source device will read the EDID of the source-device-side
VAC-5000HD. In order to enable the source device to read the EDID of the sink device, follow the
procedure below.
(1) Copy the EDID of the sink device into the sink-device-side VAC-5000HD and set it as “Copied EDID”
or “EXTERNAL (External EDID)”.
(2) Copy the EDID of the sink-device-side VAC-5000HD into the source-device-side VAC-5000HD and
set it as “Copied EDID” or “EXTERNAL (External EDID)”.
Laptop
(Source device side)
(Sink device side)
VAC-5000HD
VAC-5000HD
Projector
ON
OFF
DISTRIBUTION AMPLIFIER for HDMI
VAC-1000HD
POWER
SIGNAL
ON
OFF
DISTRIBUTION AMPLIFIER for HDMI
VAC-1000HD
POWER
SIGNAL
[Fig. 8.2] Reading EDID