SWC-2000 User
’s Guide
81
9.12.1 WEB menu links
Jump to the clicked WEB menu.
Click the desired link.
9.12.2 Blinking pattern
Sets the LED’s blinking pattern of control command button.
If the execution is not complete even after the specified time passes, the LED continues to blink until the
execution is complete.
If you specify the desired
“TIME”, the LED continues to blink until the specified time comes.
When you finish setting, click the “SEND” button.
“FLASH TIME”:
- EXECUTION: Blinks while control commands are being executed [Default]
- OFF: Does not
“1-1000sec”: Contunies to blink until the specified time (1 to 1000 seconds) comes.
9.12.3 Lighting condition
Sets when and which control command buttons will light.
Select one of the
following options for “COMMAND TALLY”.
REGISTERED: Lights when a conrol command is registered.
EXECUTION: Lights while a control command is being executed.
GROUP1 to 8: Control command buttons are divided into up to eight groups and the last clicked buttons
of each group will light.
▪
Lights only if the control command is linked to the control command button and the button is
pressed.
▪
Lights regardless of the execution result.
▪
If another button in the same group lights, the button keeps lighting.
When you finish setting, click the “SEND” button.