OPF-TH1000D/OPF-RH1000D User Guide/Command Guide
32
8.2.2 [F16] No-signal input monitoring time
You can set the monitoring time for when the source device does not output video signals due to the changes
of transmitter EDID or turning on/off the transmitter or source device.
Changing EDID
ON
OFF
The OPF requests the source
device to output video signals
Monitoring time
Hot plug
ON
OFF
Video signals from
source device
Monitoring time
Setting value
oFF: OFF
02 to 15: 2 to 15 seconds [Default: 10]
Notes:
・
If you use the power-saving function or dual monitor of the PC (source device), set this menu to “OFF”.
PCs may release or cancel those functions if they receive the request to output video signals.
・
If the set time is shorter than the timing that the source device outputs video, the source device may not
output video signals because it sets the output signals repeatedly. In these cases, set the monitoring time
longer.
Changing EDID
Monitoring
time
ON
OFF
Monitoring
time
Monitoring
time
Video output timing of source device
Video signals
from source
device
OPF requests source device to output
video signals