background image

OPF-TH1000-A/OPF-RH1000-A User’s Guide 

 

 

 

 

 

 

 

 

 

HDMI  Fiber  Optic  Extender 

 

OPF-TH1000-A/OPF-RH1000-A

 

 

User’s Guide Ver.

 

1.0.0 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  Thank you for choosing this IDK product. 

  To ensure the best performance of the  OPF-H1000, please read this User’s Guide fully and carefully 

before using it and keep this manual beside the OPF-H1000. 

 

IDK Corporation 

 

 

POWER

SIGNAL

POWER

SIGNAL

RX

O PTICAL Rx for HDMI

O PF-RH1000-A

DC

 5

V

 2A

FG

O

P

T

IC

AL

O

UT

P

UT

H

DM

I

TX

R

S-2

3

2

C

Rx

POWER

SIGNAL

POWER

SIGNAL

RX

O PTICAL Tx for HDMI

O PF-TH1000-A

DC

 5

V

 2A

FG

O

P

T

IC

AL

IN

P

UT

H

DM

I

TX

R

S-2

3

2

C

Tx

IN

P

UT

AU
D

IO

O

UT
P

UT

AU
D

IO

D

IP-SW

D

IP-SW

CL

AS

S 1 LA

SE

R PR

OD

UC

T

ラス 

レーザ製品

CL

AS

S 1 LA

SE

R PR

OD

UC

T

ラス 

レーザ製品

Summary of Contents for OPF-RH1000-A

Page 1: ...r s Guide fully and carefully before using it and keep this manual beside the OPF H1000 IDK Corporation POWER SIGNAL POWER SIGNAL RX OPTICAL Rx for HDMI OPF RH1000 A DC 5V 2A FG OPTICAL OUTPUT HDMI TX RS 232C Rx POWER SIGNAL POWER SIGNAL RX OPTICAL Tx for HDMI OPF TH1000 A DC 5V 2A FG OPTICAL INPUT HDMI TX RS 232C Tx INPUT AUDIO OUTPUT AUDIO DIP SW DIP SW CLASS 1 LASER PRODUCT クラス 1 レーザ製品 CLASS 1 ...

Page 2: ...face and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing LLC in the United States and other countries All other company and product names mentioned in this manual are either registered trademarks or trademarks of their respective owners In this manual the or marks may not be specified ...

Page 3: ... may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Note This equipment was tested with shielded cables on the peripheral devices Shielded cables must be used with the equipment to ensure compliance with FCC emissions l...

Page 4: ...nal injury if the warning is ignored or the equipment is handled incorrectly Indicates the presence of a hazard that may cause minor personal injury or property damage if the caution is ignored or the equipment is handled incorrectly Symbol Description Example Caution This symbol is indicated to alert the user Warning and caution Electrical Hazard Prohibition This symbol is intended to prohibit th...

Page 5: ...rty damage Set the power plug in a convenient place to unplug easily You can easily unplug in case of any extraordinary failure or abnormal situation and it also helps for unplugging when you do not use it for a long period Plug the power plug into appropriate outlet completely If the plug is plugged incompletely it may overheat which causes electrical shock or fire Do not use damaged plug or loos...

Page 6: ... or dusty place If the product is placed near humidifiers or dusty area it may cause fire or electric shock Do not block the vent holes If ventilation slots are blocked it may cause fire or failure due to internal heat Do not put heavy items on the product It may fall turn over and lead to injury Do not exceed ratings of outlet and wiring devices If several plugs are put in an outlet it may cause ...

Page 7: ... Cascade connection 14 5 2 HDMI input output cable 14 5 3 Fiber optical cables for long distance transmission 15 5 4 SFP Small Form factor Pluggable module 15 5 5 Audio Transmission 16 5 6 RS 232C Transmission 16 5 7 Precautions 17 5 8 Reference Attaching cable clamp 19 6 Specifications 20 6 1 Pin assignments of HDMI Type A connector 20 6 2 RS 232C pin assignments 20 6 3 Specifications 22 7 Troubl...

Page 8: ...OPF TH1000 and OPF RH1000 set Transmitter OPF TH1000 OPF TH1000 main unit x 1 AC adapter with screw type lock 1 2 m 3 94 feet x 1 Cable clamp x 1 Receiver OPF RH1000 OPF RH1000 main unit x 1 AC adapter with screw type lock 1 2 m 3 94 feet x 1 Cable clamp x 1 This User s Guide is common to both the transmitter and receiver You can download the latest version from IDK s website at http www idk co jp...

Page 9: ...into the fiber optic cables themselves Plug the attached dust caps into the optical transceivers when the fiber cable is unplugged The OPF H1000 is a transmitter and receiver set that enables HDMI signals to be transmitted long distance over fiber optical cables Input signals are transmitted without quality deterioration since they are not compressed or processed The OPF H1000 also supports RS 232...

Page 10: ...while that of multimode fiber is approximately 50 μm or 62 5 μm Singlemode fiber is suited for long distance transmission Multimode fiber is not suited for those transmissions but it is inexpensive OM3 OM4 and OS1 Fiber optical cables are defined in terms of attenuation and mode excitation bandwidth as follows Multimode OM1 to 4 Singlemode OS1 The transmission distance varies depending on the stan...

Page 11: ... fiber optical cables to connect OPF TH1000 transmitter and OPF RH1000 receiver AC adapter connector Connector for the supplied AC adapter Cable fixing hole Hole for the attached cable clamp RS 232C port Port for D sub 9 pin Audio input connectors Input connector for audio signals Analog audio signals cannot be embedded to HDMI they are sent independently Frame ground Ground for indoor ground term...

Page 12: ... for the supplied cord clamp RS 232C connector Connector for D sub 9 pin Audio output connectors Output connector for audio signals Those audio signals were not de embedded Frame ground Ground for indoor ground terminal LED lights POWER Lights when power is supplied from the AC adapter SIGNAL Lights when video signal is valid TX Lights when valid codes are sent RX Lights when the receiver fiber re...

Page 13: ...tor 5 Connect the DC plug of the supplied AC adapter to the DC jack Make sure to lock the DC jack and plug using the screw type locking mechanism Note After all connections are established plug the AC adapter to supply power OPF RH1000 Receiver RX AC adapter RS 232C 1 Input 1 Input 1 Input Multimode Fiber OM3 Max 300 m 984 25 feet OM4 Max 1 km 3280 84 feet Singlemode Fiber OS1 Max 4 7 km 15419 95 ...

Page 14: ...tion is not available in the following cases repeater that only supports HDCP pass through such as some switchers boosters and so on is included another set of OPF TH RH1000 IDK s fiber optic cable extender supporting HDCP signals Application example 5 2 HDMI input output cable Use 5 m 16 40 feet or shorter HDMI cables with Type A male connector whose pins are configured correctly ...

Page 15: ... fiber has two fibers and two connectors The duplex fiber cable is recommended for OPF H1000 but signals can be transmitted using two simplex fiber cables LC connector One of connectors for fiber optical cables Example SC connector FC connector ST connector MU connector 5 4 SFP Small Form factor Pluggable module The fiber type and extension distance to be used vary depending on the SFP module Tabl...

Page 16: ...cifications of each connected device Connection with other IDK products Cross cables Connection with a computer Cross bales IDK Product OPF TH1000 A Transmitter OPF RH1000 A Receiver Cross cable Cross cable Devices requiring straight cable connection OPF TH1000 A Transmitter OPF RH1000 A Receiver Cross cable Straight cable e g Switchers of other manufacturers Devices requiring straight cable conne...

Page 17: ... input signal resolution is set to WUXGA However some source devices can still use HDMI mode for WUXGA resolution if supported Since the OPF H1000 transmits input signals without compressing or processing signals are transmitted in 24bits pixel 8 bits component even to sink devices that support Deep Color formats Clean the connector ends of the fiber optic with a cleaner before inserting Plug the ...

Page 18: ...PF RH1000 A User s Guide 18 Notes Supply power to the AC adapter only after all connections are completed See 7 Troubleshooting if video image is not displayed appropriately on the monitor connected to the OPF H1000 ...

Page 19: ...MI cable to the OPF H1000 1 Pull up the part pointed by the short arrow and separate the bar and ring parts 2 Pass the HDMI cable through the ring 3 Insert the bar to the OPF H1000 as shown below 4 Attach the HDMI cable to the bar using the ring and insert the HDMI cable to the OPF H1000 To remove the HDMI cable perform step 1 again to separate the ring and cable Concave convex surface ...

Page 20: ...d N C 15 SCL 16 SDA 17 DDC CEC Ground 18 5 V Power 19 Hot Plug Detect N C No connection 6 2 RS 232C pin assignments D sub9 pin locations Male 1 5 RS 232C connector 6 9 RS 232C connector Pin assignments RD TD N C N C N C N C GND RTS CTS Pin No 1 3 2 4 6 5 7 9 8 Signal RD TD N C N C N C N C GND RTS CTS Signal RX data TX data Ground TX request RX request OPF H1000 A side PC side No connection No conn...

Page 21: ...on No connection Pin assignments when connected to an IDK product Note Make sure to use a cross cable RD TD N C N C N C N C GND RTS CTS Pin No 1 3 2 4 6 5 7 9 8 Signal TD RD N C N C N C N C GND RTS CTS Signal RX data TX data Ground TX request RX request OPF H1000 A side Product of other manufacturers No connection No connection No connection No connection Pin assignments when connected to a device...

Page 22: ...monitor Audio format Multi linear PCM up to 8 channels Analog audio input 5 3 5 mm Stereo mini jack L R Unbalanced signal Input impedance 11 kΩ Reference level 10 dBu Max input level 3 dBu Analog audio output 6 3 5 mm Stereo mini jack L R Unbalanced signal Output impedance 60 Ω Reference level 10 dBu Max output level 3 dBu Extension cable Suitable cable Duplex fiber cable SFP module LC connector x...

Page 23: ...ver OPF RH1000 A MM Singlemode fiber Transmitter OPF TH1000 A SM SFP module for singlemode is mounted Receiver OPF RH1000 A SM 1 HEC and ARC are not supported 2 Use an HDMI cable that is 5 m 16 4 feet or shorter 3 WUXGA is only for RB Reduced Blanking plus DVI signals 4 Deep Color is not supported 5 Analog audio input cannot be embedded in digital video 6 Analog audio output cannot be embedded fro...

Page 24: ...Are there no loose connections Are cables that are appropriate to this device being used Are signal specifications of connected devices matched to each other Are settings of the sink device correct Are there any close objects that may cause noise If additional assistance is required please perform the following tests and then contact us 1 Reboot the OPF The problem still cannot be solved 2 Connect...

Page 25: ...200 0765 Email idk_eng idk co jp URL http www idk co jp en index html Product information Support Arvanics Corporation 3 8 3 3F Yamato Higashi Yamato shi Kanagawa pref 242 0017 JAPAN TEL 81 46 259 6920 FAX 81 46 259 6920 Email info arvanics com URL http www arvanics com Information in this document is subject to change without notice All rights reserved All trademarks mentioned are the property of...