MSD-72 Series User’s Guide
66
9.6 Setting input timing
You can set input timing of analog input video if signal is input.
Since the MSD loads the optimal table from the built-in tables and adjusts the input timing automatically, you
do not need to set this menu. However, if signal which are not registered in the MSD tables are input or if part
of the output video is cut off by using the standard table registered in the MSD, set the input timing manually.
For digital inputs, you do not need to set the input timing, but if part of the video is cut off, adjust the input
timing finely.
[Table 9.4] Settable items
Function
Analog input
Digital input
Partly 1
Cannot be set
The total number of horizontal dots
Partly 1, Partly 2
Partly 2
Can be set
Can be set
Can be set
Can be set
Automatic measurement of start position
Can be set
Cannot be set
Automatic setting of input timing
Can be set
Cannot be set
Partly 3
Can be set
Partly 1
Cannot be set
Partly 1
Cannot be set
Partly 1: can be set only if analog RGB / analog YPbPr signal is input.
Partly 2: only displayed if analog video signal is input or for digital input.
Partly 3: can be set only if the device data of input signal is registered in the
MSD.