MSD-72 series Command Guide
19
3.3 Detailed descriptions
In this section, commands for MSD-7204UHD/MSD-7204UHDTB (4 outputs) are shown. For other models,
use each appropriate commands based on the number of outputs.
3.3.1 Error status
@ERR
Error status
Description
Response in case the command is not executed.
Response
@ERR, error
Parameter
error: Error status
1 = Erroneous parameter format or value
2 = Undefined command or wrong format
3 = Currently cannot be used.
4 = Not used.
5 = The command could not be executed, because the control command was not
registered.
6 = The command could not be processed since another command was being
executed.
7 = Automatic measurement of input timing failed.
8 = Loading EDID from the sink device failed.
9 = Not used.
10 = The control command was stopped according to the stop condition.
11 = The control command was stopped since the number of retries exceeded the
set value of “RETRY”.
12 = The control command of PJLink was stopped since the password did not
match.
13 = The image could not be captured since the image size to be captured
exceeded the reserved memory size.
14 = Capturing input image failed.
Getting example
Command @IOS
Response @ERR,2
@IOS is sent.
Command format error.
Remarks
-