MSD-701UHD / 702UHD / 801UHD/ 802UHD Command Guide
87
@GEC / @SEC
Control command (CEC)
Getting
Command
@GEC, no
Response
@GEC, no, delay, port, memo, error, ch_1, cec_1 (, ch_2, cec_2
・・・
)
Setting
Command
@SEC, no, delay, port, memo, error, ch_1, cec_1 (, ch_2, cec_2
・・・
)
Response
@SEC, no, delay, port, memo, error, ch_1, cec_1 (, ch_2, cec_2
・・・
)
Parameter
no: Control command number
1 to 32
delay: Delay time
0 = 0 sec. to 999999 = 999.999 sec.
port: CEC
16384 = For CEC control
memo:
Up to 14 characters of 20 to 7D except 2C (,) from ASCII codes.
error: Processing if no response from sink device.
0 = Stop processing, 1 = Continue processing
ch_1-4: Output channel
1 = OUT1A, 2 = OUT1B, 3 = OUT2A, 4 = OUT2B
cec_1-4: Control command
0 = Not controlled, 1 = POWER OFF, 2 = POWER ON
Getting commands: the control output connector and control command are
separated from each other by a comma.
Setting commands: specify output connector to be controlled and control
commands. For outputs that do not specify parameter, “Not check” is set.
Getting
example
Command
Response
@GEC,7
@GEC,7,0,16384,DISPLAY1 ON,0,1,2
Description Getting settings of control command 7.
・
Delay time: 0 ms
・
Memo: DISPLAY1 ON
・
Error: Stop
・
OUT1A sink device: Turning on.
・
Other outputs: not controlled.
Setting
example
Command
Response
@SEC,7,0,16384,DISPLAY1 ON,0,1,2
@SEC,7,0,16384,DISPLAY1 ON,0,1,2
Description Setting control command 7 as follows:
・
Delay time:0 ms
・
Memo: DISPLAY1 ON
・
Error: Stop
・
OUT1A sink device: Power ON.
・
Other outputs: not controlled.
Remarks
-