MSD-701UHD / 702UHD / 801UHD/ 802UHD Command Guide
67
3.3.9 EDID
@GED / @SED
EDID
Getting
Command
@GED
Response
@GED, edid_1, edid_2, edid_3, edid_4, edid_5, edid_6, edid_7, edid_8
Setting
Command
@SED, ch_1, edid_1 (, ch_2, edid_2
・・・
)
Response
@SED, ch_1, edid_1 (, ch_2, edid_2
・・・
)
Parameter
edid_1-8: EDID
0 = Built-in EDID [Default],
1 = OUT1A MONITOR,
2 = OUT1B MONITOR,
3 = OUT2A MONITOR,
4 = OUT2B MONITOR,
101 to 108 = COPY DATA 1 to COPY DATA 8
ch_1-8: Input channel
0 = All digital inputs, 1 = IN1 to 8 = IN8
Getting
example
Command
Response
@GED
@GED,0,0,0,3,0,0,0,0
Description Getting the set EDID.
IN4: EDID of the sink device that is connected to OUT3,
other inputs: built-in EDID
Setting
example
Command
Response
@SED,2,3
@SED,2,3
Description Setting IN2: EDID that is read from the sink device connected to OUT3.
Remarks
These commands are only for digital input.
IN6 and IN7: If “0” (Analog signal) is selected for “
”, “-1” is acquired and the setting cannot be valid.
In order to use a copied data, read EDID data from the sink device in “
” in advance.