FDX-32 Users Guide
65
8.8.6 Linear PCM Audio [EDID LINEAR PCM]
The maximum sampling frequency of PCM audio that is output from the source device
【
See: 8.8.1 EDID resolution [EDID DATA]
Using menu
EDID → EDID LINEAR PCM
For
Each input connector (IN1 to IN32)
Set value
32kHz: 32 kHz
44.1kHz: 44.1 kHz
48kHz: 48 kHz
[Default value]
88.2kHz: 88.2 kHz
96kHz: 96 kHz
192kHz: 192 kHz
【
NOTE
】
If you do not press the
“SET” key, the setting is not changed.
For LCD monitors and the like, some audio formats are not supported. Select the audio format and
sampling frequency that are supported by the connected devices.
If EDID resolution is set to “05” to “24”, this menu will be valid.
Channels that do not have an input slot board cannot be selected in this menu.
8.8.7 AC-3 Dolby Digital Audio [EDID AC-3/Dolby D]
The maximum sampling frequency of AC-3 Dolby Digital Audio that is output from the source device
【
See: 8.8.1 EDID resolution [EDID DATA]
Using menu
EDID → EDID AC-3/Dolby D
For
Each input connector (IN1 to IN32)
Set value
OFF [Default]
32kHz
44.1kHz
48kHz
【
NOTE
】
If you do not press the
“SET” key, the setting is not changed.
For LCD monitors and the like, some audio formats are not supported. Select the audio format and
sampling frequency that are supported by the connected devices.
If EDID resolution is set to “05” to “24”, this menu will be valid.
Channels that do not have an input slot board cannot be selected in this menu.