FDX-08 Command Guide
74
@GOI
Sink device status
Function
Getting
Format
@GOI
Return value
@GOI,status_1,
・・・
status_8
Parameter
status_1 to status_8: Sink device status
-2 = Output board is not mounted.
Upper two digits = Sink device HDCP status,
Lower three digits = HDCP authentication status between sink device
Upper two digits = Sink device HDCP status
Example
Description
00
Sink device is not connected.
01
HDCP of sink device is not checked.
02
HDCP compliant sink device is connected.
03
Non-HDCP compliant sink device is connected.
Lower three digits = HDCP authentication status between sink device
Example
Description
000
Signal with HDCP is not input.
001
Being HDP authentication processing
002
Being HDP authentication processing
003
Being HDP authentication processing
004
HDCP authentication succeeded
005
HDCP authentication failed
Example
@GOI
@GOI,02004,01000,00000,-2,-2,-2,-2,-2
Getting all statuses of sink device
- Output channel 1:
Sink device supporting HDCP is
connected and authentication has
been succeeded.
- Output channel 2:
HDCP of sink device has not been
founded and signal with HDCP is not
input.
- Output channel 3:
Sink device is not connected and
signal with HDCP is not input.
- Output channel 4 to 8:
Output board is not mounted.
Remarks
Supported since firmware ver.2.xx