4/10/2006
– MPC6
PC6 OSCILLATOR
Operation / Maintenance
Manual
SERIAL NO. ___________________
Page 1: ...4 10 2006 MPC6 PC6 OSCILLATOR Operation Maintenance Manual SERIAL NO ___________________...
Page 2: ...PC6 OSCILLATOR OPERATION MAINTENANCE MANUAL CONTENTS CONTENTS 1 UTILITIES HOOK UP 3 2 OSCILLATOR CYCLE RATE 5 2 1 ADJUSTMENT INSTRUCTIONS 5...
Page 3: ...0 610 1 4 4 1 bar and 20 80 psig Maxim 25 50 1 4 5 5 bar clean dry air or nitrogen Refer to pump operation manual for maximum temperature pressure chart The Mufflers on the Oscillator control Module c...
Page 4: ...PAGE 4 PC6 OSCILLATOR OPERATION MAINTENANCE MANUAL Figure 1 2 WARNING Particulate water and oils in the air supply can damage the oscillator...
Page 5: ...osity Max cycle rate of unit is 300 CPM Adjust air supply pressure to 10 psig over desired discharge pressure Min 15 psig Max 60 psig Calculate minimum oscillation rate based on desired flow rate Cycl...