background image

0901159 Rev: B (03/05) 

Page 1 of 8 

INTRODUCTION 

Dairy Chem Systems are designed to dispense non-foaming dairy cow teat dip products from a chemical storage 
vessel to a teat dip spray head or fill valve. VS versions use an external vacuum switch on the pipeline to control 
dispensing only when milking lines are in use. Systems with dual-pump configuration can be setup to operate in the 
following ways: 

• 

Run both pumps simultaneously to inject two different chemicals. 

• 

Run one pump at a time, but alternate between pumps at various intervals (using the selector valve on units so 
equipped) to extend the life of both pumps. 

• 

Run one pump at a time, but only switch pumps when needed (using the selector valve on units so equipped) to 
keep one as a spare. 

SPECIFICATIONS 

 

 

 

 

SAFETY PRECAUTIONS 

• 

Read and understand the MSDS sheets for the chemicals that will be used — consult your chemical supplier if you 
have any questions. 

• 

Always wear safety goggles and protective gloves while handling chemicals. 

• 

Avoid contact of chemicals with skin and eyes. If contact occurs, rinse affected area with water for 15 minutes, and 
seek medical attention, if needed. 

MAINTENANCE 

• 

Periodically drain the bowl on the air regulator/filter by pushing up the stem on the bottom of the bowl till the water 
runs out. 

• 

The bowl can be removed (by turning counter-clockwise) to clean the filter element. When replacing the bowl, be 
sure that the O-ring is properly positioned on top of the bowl. 

INSTRUCTION MANUAL 

Chemical Compatibility 

Santoprene: acids, alkalines, soaps, alcohols, ketones. 

Air Operated Pump Materials 

Polypropylene Body w/ Santoprene Seals and 
Diaphragm. 

Air Requirements / Consumption 

Minimum 40 PSI / Maximum 80 PSI clean dry air 
5-10 SCFM during operation. 