Identiv PRIMIS FR-50-40-1 Installation Manual Download Page 1

identiv.com  

  [email protected]  

  +1 888-809-8880

Primis Single Port Bridge

 

Installation Guide

PART NUMBERS

FR-50-40-1, FR-50-40-1L

FR-50-24-1

PHYSICAL SPECIFICATIONS

Length

76 mm (3.00 in.)

Width

47 mm (1.85 in.)

Height

17 mm (0.67 in.)

Weight

26 g (1.20 oz.)

Max Readers

1

Max Input

2

Max Output

1

Electrical:

 UL294 and UL294B 

Power over ethernet:

 IEEE 802af

EMI Radiation:

 FCC Part 15 Class B

SUMMARIZED LEVELS OF  

ACCESS CONTROL COMPONENTS

Destructive Attack

Level I

Line Security

Level I

Endurance

Level I

Standby Power

Level I

Single Point Locking

Level I

BASE PLATE MOUNTING

Dimension

Millimeters

Inches

A

116.07

4.57

B

78.74

3.10

C

15.24

0.60

D

85.59

3.37

E

10.16

0.40

F

58.42

2.30

E

D

A

C

B

F

Primis Bridges should only be installed in dry, non-condensing 
environments. The ambient temperature of the environment should 
range between -40°C and 50°C.      

Primis Encryption Bridges should only be mounted to non-conductive 
surfaces. Incorrect mounting may short-circuit the electronics, which will 
cause it to malfunction.

DC power, reader, input contact, and output device wires should 
be between 16-28 AWG. They should also be stripped 5.5mm to 

contact with each other.

INSTALLATION REQUIREMENTS

For each of the following steps, be sure to reference the wiring 

diagram on page 2 for additional details: 

1. 

Connect a Wiegand Reader to the Wiegand Reader Input on the 
Primis Bridge.

 

A. 

If the reader has a shield wire, connect the shield wire 
to the 0v terminal on the Wiegand Reader Input. If an 
extension cable is used between the reader and the 
Primis Bridge, connect the reader’s shield wire to the 
cable’s shield, then connect the cable’s shield to the 0v 
terminal on the Wiegand Reader Input.

B. 

Any unused wires on the reader must be evenly snipped 
and have their tips insulated using electrical tape or 
equivalent. The shield wire on the reader must also be 
completely insulated. 

2. 

If you have any supervised input contacts, wire them to the Digital 
Contact Inputs using Method 1 or Method 2. 

3. 

If you have any non-supervised input contacts, wire them to the 
Digital Contact Inputs. 

4. 

If you have a relay output contact, wire it to the Relay Output.

5. 

Supply power to the Primis Bridge using either or both of the 
following methods:

A. 

A 2.25 – 5.25 W Power over Ethernet (PoE) port on an 
Ethernet switch connected to the Primis Bridge using a 
Cat5e or Cat6 cable.

B. 

12 – 16 Vdc & 350 mA (300 mA external & 50 mA 
internal) DC power connected directly to the TB1 terminal 
on the Primis Bridge.

6. 

If you are not using PoE to power your Primis Bridge, connect 
a Cat5e or Cat6 cable from any port on an Ethernet switch to the 
RJ- 45 connector on the Primis Bridge. 

Note:

 Ethernet only 

supports a maximum cable length of 100 m. 

7. 

INSTALLATION PROCEDURE

To configure and add the Freedom Bridge to a Primis
Server, refer to the Primis Solution Guide manual.

Reviews: