Unpairing procedure between MorphoAccess and PC
This procedure is useful when a couple of MorphoAccess Sigma Wave and PC Wave are
changed by new devices. This unpairing procedure explain you how to disassociate a
couple of device.
Procedure:
1.
Unconnect the RJ45 cable on the port “PC Wave” of the Ethernet switch to unconnect
the PC and MorphoAccess Sigma Wave. It is not required to have the external network
connected. Following screen will be displayed once the cable has been disconnected :
2.
On the MorphoAccess Sigma Wave side, go in administration menu :
Select settings menu