Annex 1 : Maintenance
2015_2000009096 V6
January 2019
IDEMIA
D
OCUMENT
–
R
EPRODUCTION AND
D
ISCLOSURE
F
ORBIDDEN
77
Anti-tamper / anti-pulling switches
Please refer also to “Tamper Switch” section.
These switches are activated as soon as there is enough pressure applied on the
terminal against the wall. They are deactivated as soon as this pressure is not big
enough, e.g. when the terminal is pulled out of the wall.
When the switches are deactivated, the MorphoAccess Sigma Wave terminal acts as
required by the related configuration key (see MorphoWave™ OEM Administrator /
User Guide for key configuration description):
Ignore the event (default): useful during normal maintenance operations.
Send an alarm message to the Central Access Controller, through the usual channel
of the access control result messages (Wiegand, DataClock, RS485, Ethernet An
alarm switch (relay contact) is directly available on block terminal «tamper switch
pins». Please refer to “Wiring overview” and to “Tamper Switch” sections.
Generate an audible alarm signal with the speaker and an alert message on the
screen.