LSPS-R Series - IEC Safety Limit Switches     EN 50047 

  

 

 
             

 

       

 

                                                

 

 

 
                                  

 
 

 
                    

                                                                        

                                                                                                                                                          

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

5.

 

Always ensure that when fitting electrical conductors that they are routed correctly and do not interfere with the switch cover during fitting.                                                                       
Maximum conductor size is 1.5 sq.mm, contact terminal tightening torque is 1Nm. 

6.

 

Tightening torque for the lid screw is and cable glands is1Nm to maintain IP rating. 

7.

 

Always use M4 mounting bolts and ensure 2Nm tightening torque for robust fitting. 

8.

 

The switches are reset by pulling out the blue pin after switch actuation. 

     9.       The safety functions and mechanics must be tested regularly. For applications were infrequent guard access is foreseeable, the system must have a manual function test to detect a    
               possible accumulation of faults. At least once per month for PLe Cat3/4 or once per year for PLd Cat3 (ISO13849-1).  Where possible it is recommended that the control system of the     
               machine demands and monitors these tests, and stops or prevents the machine from starting if the test is not done. (See ISO14119). 

 

Maintenance: 

Every Week:        Check the switch actuator and body for signs of mechanical damage and wear. Replace any switch showing damage. 
Every 6 Months:   Isolate power and remove cover. Check screw terminal tightness and check for signs of moisture ingress.  Never attempt to repair any switch.  
 

Contact Blocks /Connections

:          

                          

 

 

 

Technical Specification: 

 
 
 
 

 
 
 
 

Conforming to standards  

ISO14119  IEC947-5-1  UL60947-5-1  EN50047 ISO13849-1 

Positive Opening Operation  

NC  Contacts 

Utilization Category  

AC15   A300    240V. 3A. 

Actuation Force/Torque for Positive Opening 

12N. linear types     1.0Nm. rotary types 

Min Current   

5V, 5mA, DC  

Thermal Current (Ith)  

10A  

Rated Insulation Voltage  

300VAC  

Rated Impulse Withstand Volt  

2500VAC  

Max. Switching Speed  

250mm/s  

Case Material  

UL approved glass-filled plastic 

Roller Material  

Various Polymers Steels 

Enclosure Protection   

IP67  

Operating Temperature  

Min. -25°C    Max 80°C 

Mechanical Life Expectancy  

2,500,000 Cycles 

Electrical Life Expectancy at full load 

100,000 Cycle min. 

Vibration  

IEC 68-2-6, 10-55Hz   0.35mm 

Conduit Entry  

M20    or    ½” NPT    

Fixing    

2 x M4 

 

 

 

 

Incorrect 

Incorrect 

Correct 

 

Stop 

    

Correct 

      Operating Instructions 

Application: 

IDEM LSPS-R Limit Switches with Reset Button are designed to be mounted for position sensing of moving applications e.g. guard doors, conveyors, machine beds, elevators etc. 
They are available with linear plungers, rotary levers or roller plungers and either slow or snap action contacts. All contact blocks are positively operated to satisfy IEC 60947-5-1. 
 

Operation: 

Operation of the switches is achieved by a sliding actuation of the moving object to cause deflection of the switch plungers or levers. 
For safety applications it is important that the moving object does not pass completely over the switch actuators so as to cause the actuator to return to its original position. 
 

Installation guide:  Correct Mounting of Limit Switches is critical to obtain optimum performance and ensure safety reliability. 

Installation of all switches must be in accordance with a risk assessment for the individual application.  
Installation must only be carried out by competent personnel and in accordance with these instructions. 

 
1.

 

Never use the switch as a mechanical stop.  Ensure that the actuator is protected from mechanical shock. 

2.

 

For switches with Linear actuators the actuating direction and force from the moving object should be applied in line with the axis of the plunger. 

3.

 

For switches with Rotary actuators or rollers the operating cam from the moving object should be designed such that the switch is never operated beyond it’s over travel position. Always use a 
30 degree tapered actuating cam. 

4.

 

The heads of the switch can be rotated to obtain the best switch orientation by removing the 4 head screws and rotating the head through 90 degrees. Always ensure the 4 head screws are 
tightened to 1Nm to ensure switch robustness.  

 

   

WARNING:  DO NOT DEFEAT, TAMPER, OR BYPASS THE SAFETY FUNCTION.   

                                        FAILURE TO DO SO CAN RESULT IN DEATH OR SERIOUS INJURY.  
 
         AVERTISSMENT: NE PAS DESACTIVER, MODIFIER, RETIRER, OU CONTOURNER  
                                       CETI INTERVERROUILLAGE IL PEUT EN RESULTER DES   
                                       BLESSURES GRAVES DU PERSONNEL UTILISATEUR.   

Original Instructions. 

 
To request this data sheet in other languages please contact 

[email protected]

 

Um dieses Datenblatt in Deutscher Sprache wenden Sie sich bitte anfordern 

[email protected]

 

Pour obtenir cette fiche en Français, veuillez contacter 

[email protected]

 

Para solicitar esta hoja de datos en Español, por favor contacto con 

[email protected]

 

Reviews: