7: HMI F
UNCTION
7-34
FC6A S
ERIES
M
ICRO
S
MART
A
LL
-
IN
-O
NE
T
YPE
U
SER
’
S
M
ANUAL
FC9Y-B1722
Modifying a Word Device Value
This section describes an example of changing D0002 to 500 while the user program is running.
1.
On the standard screen, press the
(ESC) +
(OK) buttons.
The system menu is displayed.
2.
Select
Device Monitor
with the
(up) and
(down) buttons and press the
(OK) button.
The FC6A Series MicroSmart switches to the Device Monitor mode.
3.
Select device type: D (Data Register) with the
(left) and
(right) buttons and press and hold the
(OK) button.
4.
Select D0002 with the
(up) and
(down) buttons and press the
(OK) button.
5.
Move the digit with the
(right) button and modify the value with the
(up) and
(down) buttons.
6.
Press the
(OK) button to confirm.
Running
13:30:40
2015/DEC/01/TUE
Stop
External Memory
Device Monitor
Status Monitor
D
D
D
D
0
00000:
00010:
00020:
00030:
0
0
0
D
0
00000:
00010:
00020:
00030:
D
0
D
0
D
0
Change Device Val.:
D 00002:
00
5
00
DEC (W)
'
'
'
'
0
00000:
00010:
00020:
00030:
0
500
0
Summary of Contents for FC6A series
Page 1: ...B 1722 2 FC6A SERIES All in One Type User s Manual ...
Page 10: ...TABLE OF CONTENTS Preface 9 FC6A SERIES MICROSMART ALL IN ONE TYPE USER S MANUAL FC9Y B1722 ...
Page 28: ...1 GENERAL INFORMATION 1 18 FC6A SERIES MICROSMART ALL IN ONE TYPE USER S MANUAL FC9Y B1722 ...
Page 286: ...6 DEVICES 6 32 FC6A SERIES MICROSMART ALL IN ONE TYPE USER S MANUAL FC9Y B1722 ...
Page 334: ...7 HMI FUNCTION 7 48 FC6A SERIES MICROSMART ALL IN ONE TYPE USER S MANUAL FC9Y B1722 ...
Page 340: ...8 INSTRUCTIONS REFERENCE 8 6 FC6A SERIES MICROSMART ALL IN ONE TYPE USER S MANUAL FC9Y B1722 ...
Page 360: ...9 FUNCTIONAL MODULES 9 20 FC6A SERIES MICROSMART ALL IN ONE TYPE USER S MANUAL FC9Y B1722 ...
Page 368: ...10 ANALOG CARTRIDGE 10 8 FC6A SERIES MICROSMART ALL IN ONE TYPE USER S MANUAL FC9Y B1722 ...