2 Operational Check
Screen and Menu
4 Appendix
1 Overview
3-8
Menu item descriptions
No.
Name
Description
(13) Setting
Sets the bank that is selected in bank number display 2 as the bank at start.
(When Advanced settings (20) are enabled)
(14) Reload
Reloads the selected bank. Use this when the currently selected bank becomes un-
known due to resetting the WB1F.
(15) Select
Confirms the bank selected by Bank number selection (10) for bank number display 2.
(When advanced settings are enabled)
(16) Initial
Resets the WB1F to the factory defaults.
(17) Reset
Resets the WB1F power suply.
z
File operation
No.
Name
Description
(18) Upload
Uploads all WB1F setting values to a CSV file.
(19) Download
Downloads a CSV file created by uploading to the WB1F.
z
Read settings
No.
Name
Description
(20) Advance settings
When this checkbox is selected, you can switch the Bank number selection (10) and
Initial (16).
A bank is a region where setting values are saved. The WB1F has eight banks.
You can configure setting values for bank number 0 to bank number 7, which allows you to switch between and use a
maximum of eight patterns of settings.
The procedures to send and receive setting values and to switch the bank number (selected/start) are as follows.
■
Procedure to receive setting values
1
Click
Receive (6)
.
The setting values for the bank that is displayed in Bank number display 2 (9) are displayed on the computer.
■
Procedures to transmit setting values
1
After receiving the setting values, edit them in the edit area.
2
Click
Send (5)
after you have finished editing the setting values.
The current values are applied to the WB1F.
3
Click
B-save (12)
.
The current values are saved to the currently slected bank number.
If you turn off the WB1F power supply without performing the procedure to Send the setting values, the
changed settings will not be applied to the WB1F. The setting values will also be applied for RS-232 config-
uration items after B-save (12) is clicked and the unit is reset.