3 Project Settings Dialog Box
3-28
SmartAXIS Touch User's Manual
Functions Available with the Serial Interface
The following functions can be used with the serial interface.
• Barcode reader connection
F
Refer to Chapter 22 “5 User Communication” on page 22-7.
Functions Available with the Ethernet Interface
The following functions can be used with the Ethernet interface.
• Online
F
Refer to Chapter 23 “Online Function” on page 23-1.
• Debug
F
Refer to Chapter 24 “Monitor Function” on page 24-1.
Functions Available with the USB Interface
The following functions can be used with a USB interface.
• Online
F
Refer to Chapter 23 “Online Function” on page 23-1.
• Debug
F
Refer to Chapter 24 “Monitor Function” on page 24-1.
• Barcode reader connection
F
Refer to Chapter 22 “5 User Communication” on page 22-7.
■
Interface Settings
The items that can be configured vary based on the communication interface selected under
Interface
Configuration
.
When Port is selected under Interface Configuration
Protocol:
Selects the Protocol to use with the serial interface (RS232C) from the following.
N/A
,
External Device Communication
,
User Communication 1
,
User Communication 2
,
User Communication 3
Selects the protocol to use with the serial interface (RS422/485) from the following.
N/A
,
External Device Communication
,
O/I Link Master
,
O/I Link Slave
,
User
Communication 1
,
User Communication 2
,
User Communication 3
This communication interface is not used when
N/A
is selected.
Baud Rate:
Selects the communication speed with the external device from the following.
1200
,
2400
,
4800
,
9600
,
19200
,
38400
,
57600
,
115200
,
187500
The baud rate that can be configured varies based on
Protocol
.
Data Bits:
Selects the data length as
7
or
8
.
This option can only be configured when
External Device Communication
,
User
Communication 1
,
User Communication 2
, or
User Communication 3
is selected for
Protocol
.
Stop Bits:
Selects the stop bits as
1
or
2
.
This option can only be configured when
External Device Communication
,
User
Communication 1
,
User Communication 2
, or
User Communication 3
is selected for
Protocol
.
Parity:
Selects the parity from the following.
None
,
Odd
,
Even
This option can only be configured when
External Device Communication
,
User
Communication 1
,
User Communication 2
, or
User Communication 3
is selected for
Protocol
.
Flow Control:
Selects the flow control method as
None
or
ER
according to the external device being used.
This option can only be configured when
External Device Communication
is selected for
Protocol
.
Serial Interface:
Selects the standard for the serial interface to use from the following.
RS232C
,
RS422/485 2-wire, RS422/485 4-wire
RS422/485 4-wire
can only be configured when
User Communication 1
,
User
Communication 2
, or
User Communication 3
is selected for
Protocol
.
Summary of Contents for SmartAXIS Touch FT1A Series
Page 1: ...FT1A Series FT9Y B1390 4 SmartAXIS Touch User s Manual ...
Page 22: ...Contents Preface 21 SmartAXIS Touch User s Manual ...
Page 240: ...6 Using Library Screens 4 36 SmartAXIS Touch User s Manual ...
Page 416: ...2 Multi State Lamps 8 26 SmartAXIS Touch User s Manual ...
Page 558: ...9 Calendar 9 142 SmartAXIS Touch User s Manual ...
Page 668: ...6 Timer 11 52 SmartAXIS Touch User s Manual ...
Page 754: ...4 Using Data and Detected Alarms 13 34 SmartAXIS Touch User s Manual ...
Page 792: ...4 Using the Data 14 38 SmartAXIS Touch User s Manual ...
Page 810: ...4 Using the Data 15 18 SmartAXIS Touch User s Manual ...
Page 870: ...3 Text Manager 19 16 SmartAXIS Touch User s Manual ...
Page 924: ...6 Important Notes 20 54 SmartAXIS Touch User s Manual ...
Page 1036: ...5 User Communication 22 74 SmartAXIS Touch User s Manual ...
Page 1092: ...2 Monitoring on the Touch 24 26 SmartAXIS Touch User s Manual ...
Page 1142: ...2 Word Devices 27 18 SmartAXIS Touch User s Manual ...
Page 1186: ...2 Analog Cartridge 29 34 SmartAXIS Touch User s Manual ...
Page 1194: ...3 Handling Problems 30 8 SmartAXIS Touch User s Manual ...