FT1A S
MART
A
XIS
U
SER
’
S
M
ANUAL
FT9Y-B1382
5-11
5: B
ASIC
I
NSTRUCTIONS
TMLO, TIMO, TMHO, and TMSO (Off-Delay Timer)
Four types of timedown off-delay timers are available; 1-sec off-delay timer TMLO, 100-ms off-delay timer TIMO, 10-ms off-delay
timer TMHO, and 1-ms off-delay timer TMSO. A total of 100 (FT1A-12) or 200 (other FT1A series) on- and off-delay timers can be
programmed in a user program. Each timer must be allocated to a unique number T0 through T199.
The valid device range depends on the CPU module type. For details, see pages 6-1 and 6-2.
The preset value can be 0 through 65535 and designated using a constant or a data register.
TMLO (1-sec Off-delay Timer)
TIMO (100-ms Off-delay Timer)
TMHO (10-ms Off-delay Timer)
TMSO (1-ms Off-delay Timer)
Timer
Device Address
Range
Increments
Preset Value
TMLO (1-sec off-delay timer)
T0 to T199
0 to 65535 sec
1 sec
Constant:
0 to 65535
TIMO (100-ms off-delay timer)
T0 to T199
0 to 6553.5 sec
100 ms
Data registers:
D0 to D1999
TMHO (10-ms off-delay timer)
T0 to T199
0 to 655.35 sec
10 ms
TMSO (1-ms off-delay timer)
T0 to T199
0 to 65.535 sec
1 ms
I1
I0
T0
Ladder Diagram (TMLO)
TMLO
4
T0
I0
ON
OFF
T0
ON
OFF
I1
ON
OFF
Q0
ON
OFF
Timing Chart
4 sec
Q0
LOD
TMLO
LOD
AND
OUT
I0
T0
4
I1
T0
Q0
Program List
Instruction
Data
I1
I0
T1
Ladder Diagram (TIMO)
TIMO
20
T1
I0
ON
OFF
T1
ON
OFF
I1
ON
OFF
Q1
ON
OFF
Timing Chart
Q1
2 sec
LOD
TIMO
LOD
AND
OUT
I0
T1
20
I1
T1
Q1
Program List
Instruction
Data
I1
I0
T2
Ladder Diagram (TMHO)
TMHO
100
T2
I0
ON
OFF
T2
ON
OFF
I1
ON
OFF
Q2
ON
OFF
Timing Chart
1 sec
Q2
LOD
TMHO
LOD
AND
OUT
I0
T2
100
I1
T2
Q2
Program List
Instruction
Data
I1
I0
T3
Ladder Diagram (TMSO)
TMSO
500
T3
I0
ON
OFF
T3
ON
OFF
I1
ON
OFF
Q3
ON
OFF
Timing Chart
0.5 sec
Q3
LOD
TMSO
LOD
AND
OUT
I0
T3
500
I1
T3
Q3
Program List
Instruction
Data
Summary of Contents for microsmart pentra
Page 1: ...FT1A SERIES FC9Y B1382 Ladder Programming Manual ...
Page 6: ...Preface 5 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 104: ...7 DATA COMPARISON INSTRUCTIONS 7 10 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 122: ...8 BINARY ARITHMETIC INSTRUCTIONS 8 18 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 138: ...10 SHIFT ROTATE INSTRUCTIONS 10 12 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 162: ...11 DATA CONVERSION INSTRUCTIONS 11 24 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 188: ...12 CALENDAR COMPARISON INSTRUCTIONS 12 26 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 198: ...15 REFRESH INSTRUCTIONS 15 4 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 202: ...16 INTERRUPT CONTROL INSTRUCTIONS 16 4 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 266: ...20 DUAL TEACHING TIMER INSTRUCTIONS 20 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 318: ...25 USER COMMUNICATION INSTRUCTIONS 25 22 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...