4: I
NSTRUCTIONS
R
EFERENCE
4-12
FT1A S
MART
A
XIS
U
SER
’
S
M
ANUAL
FT9Y-B1382
32-bit Data Storage
When the double-word (D) or long (L) data type is selected, the data is stored in the consecutive devices in the following manner
according to the 32-bit data storage setting configured in
Function Area Settings
under
Device Settings
.
For applicable devices and instructions, see Chapter 5 "Special Functions” – “32-bit Data Storage Setting" in the FT1A Series Pro/
Lite User's Manual.
Word devices:
The data storage when
From Upper Word
is selected under
Device Settings
When D0 is specified as the source or destination device, the upper word is stored in D0 and the lower
word is stored in D1.
Double word data (constant)
The data storage when
From Lower Word
is selected under
Device Settings
When D0 is specified as the source or destination device, the lower word is stored in D0 and the upper
word is stored in D1.
Double word data (constant)
Bit devices:
The data storage when
From Upper Word
is selected under
Device Settings
When R0 is specified as the source or destination device, the upper word is stored in R0 to R15 and the
lower word is stored in R16 to R31.
Double word data (constant)
The data storage when
From Lower Word
is selected under
Device Settings
When R0 is specified as the source or destination device, the lower word is stored in R0-R15 and the
upper word is stored in R16-R31.
Double word data (constant)
Upper word
Lower word
(Hexadecimal)
Upper word
Lower word
D0:
D1:
1 2 3 4 5 6 7 8
5 6 7 8
1 2 3 4
Upper word
Lower word
(Hexadecimal)
Lower word
Upper word
D0:
D1:
1 2 3 4 5 6 7 8
1 2 3 4
5 6 7 8
Upper word
Lower word
(Hexadecimal)
Upper word
Lower word
R0 to R15:
R16 to R31:
1 2 3 4 5 6 7 8
5 6 7 8
1 2 3 4
R15
R0
R31
R16
Upper word
Lower word
(Hexadecimal)
Lower word
Upper word
R0 to R15:
R16 to R31:
1 2 3 4
5 6 7 8
R15
R0
R31
R16
1 2 3 4 5 6 7 8
Summary of Contents for microsmart pentra
Page 1: ...FT1A SERIES FC9Y B1382 Ladder Programming Manual ...
Page 6: ...Preface 5 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 104: ...7 DATA COMPARISON INSTRUCTIONS 7 10 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 122: ...8 BINARY ARITHMETIC INSTRUCTIONS 8 18 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 138: ...10 SHIFT ROTATE INSTRUCTIONS 10 12 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 162: ...11 DATA CONVERSION INSTRUCTIONS 11 24 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 188: ...12 CALENDAR COMPARISON INSTRUCTIONS 12 26 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 198: ...15 REFRESH INSTRUCTIONS 15 4 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 202: ...16 INTERRUPT CONTROL INSTRUCTIONS 16 4 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 266: ...20 DUAL TEACHING TIMER INSTRUCTIONS 20 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 318: ...25 USER COMMUNICATION INSTRUCTIONS 25 22 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...