Repeat Cycles
When a data register is assigned to repeat, as many consecutive data registers, as the repeat cycles, are used to transmit data in
the same conversion type and transmit digits.
Example:
Data from data registers starting with D10 is converted in BCD to ASCII and is transmitted according to the designated repeat
cycles.
BCC (Block Check Character)
Block check characters can be appended to the transmit data. The start position for the BCC calculation can be selected from the
first byte through the 15th byte. The BCC can be 1 or 2 digits.
000Ch
D10
0022h
D11
0038h
D12
Data register No.:
Transmit digits:
Conversion type:
D10
2
BCD to ASCII
000Ch
D10
“1”
(31h)
“2”
(32h)
“3”
(33h)
“4”
(34h)
00012
Repeat 1
0022h
D11
Decimal value
00034
BCD to ASCII conversion
Repeat 2
ASCII Data
(1) Repeat cycles = 2
000Ch
D10
“1”
(31h)
“2”
(32h)
“3”
(33h)
“4”
(34h)
00012
Repeat 1
0022h
D11
Decimal value
00034
BCD to ASCII conversion
Repeat 2
0038h
D12
00056
Repeat 3
“5”
(35h)
“6”
(36h)
ASCII Data
(2) Repeat cycles = 3
STX
BCC calculation start position can be selected from this range.
1st
“A”
2nd
“B”
3rd
“C”
4th
“D”
5th
“E”
6th
“0”
15th
CR
16th
LF
17th
BCC
18th
BCC
19th
BCC calculation range when starting with the 1st byte of the data.
BCC
(2 digits)