WindO/I-NV4 User’s Manual
11-69
4 Meter
11
Charts
●
Range
Tab
The
Range
tab is only displayed in Advanced mode.
■
Show Range
Select this check box to show ranges on the meter and configure the number of ranges, range colors, and limits.
Ranges can only be configured when
Standard
or
None
is selected under
Image Type
on the
View
tab.
Number of Ranges:
Specifies the number of ranges (1 to 5).
Range Color:
Selects the range color (color: 256 colors, monochrome: 16 shades).
Click this button to display the Color Palette. Select a color from the Color Palette.
Limits:
Specifies the limit for the range.
(Data Type):
Selects the data type to use for the limit.
Value:
Uses a constant value.
Device Address: Uses a value of device address.
The limit varies based on the data type selected with
Data Format
on the
General
tab. For
details, refer to Chapter 2 “1.1 Available Data” on page 2-1.
When
Device Address
is selected for (Data Type), the minimum and maximum can be
specified in the word device.
Click
to display the Tag Editor. For the device address configuration procedure, refer to
Chapter 2 “5.1 Device Address Settings” on page 2-68.
If the data displayed in the meter is invalid, 1 is written to System Area 2 Processing error bit (address
2, bit 5), and an error message is displayed. For details, refer to Chapter 4 “Processing error” on
page 4-32 and Chapter 36 “Processing error” on page 36-3.
An error occurs in the following states:
• The setting of
Minimum
,
Maximum
, or ranges are invalid, or the
Minimum
and
Maximum
are the
same values.
•
Data Type
is
BCD4(B)
,
BCD8(EB)
, or
Float32(F)
and the value cannot be expressed with the data
type selected for the read data
If an error occurs, only the flange is initially displayed. Then once the meter is displayed, it doesn't show an
update.
Example:
180-degree meter, data minimum is 0, maximum is 100, the number of ranges is set to 5
The limit between range 1 and 2: 20
The limit between range 2 and 3: 40
The limit between range 3 and 4: 60
The limit between range 4 and 5: 80
Range 1
Range 2
Range 3
Range 4
Range 5
0
100
20
80
40
60
Summary of Contents for MICRO/I HG4G-CJT22 F-B Series
Page 1: ...B 1701 11 User s Manual ...
Page 26: ...Preface 25 WindO I NV4 User s Manual ...
Page 106: ...5 WindO I NV4 Common Operations and Settings 2 74 WindO I NV4 User s Manual ...
Page 254: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual ...
Page 362: ...5 Screen Restrictions 5 28 WindO I NV4 User s Manual ...
Page 402: ...3 Text 7 30 WindO I NV4 User s Manual ...
Page 574: ...9 Potentiometer 8 172 WindO I NV4 User s Manual ...
Page 1052: ...4 Using the Data 15 22 WindO I NV4 User s Manual ...
Page 1170: ...6 Important Notes 20 60 WindO I NV4 User s Manual ...
Page 1200: ...5 Restrictions 22 18 WindO I NV4 User s Manual ...
Page 1260: ...5 Editing User Accounts on the MICRO I 23 60 WindO I NV4 User s Manual ...
Page 1322: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual ...
Page 1414: ...4 E mail Function 28 66 WindO I NV4 User s Manual ...
Page 1554: ...3 Settings 34 14 WindO I NV4 User s Manual ...
Page 1642: ...2 Handling Problems 36 6 WindO I NV4 User s Manual ...
Page 1652: ...5 Text Alignment A 10 WindO I NV4 User s Manual ...
Page 1664: ...Index 12 WindO I NV4 User s Manual ...