WindO/I-NV4 User’s Manual
35-35
2 HG4G/3G, HG2G-5F
35
MICRO/I Spec
ification
s
2.8 Wiring
●
Power Supply Terminal
• Pin assignment is shown in the following table.
• Use applicable cables for wiring and recommended ferrules (made by Phoenix Contact) as follows.
●
Grounding Cautions
If you decide to use a single power supply for the HG4G/3G, HG2G-5F with more than one external device, take extra
precautions. Some external devices may produce electrical noise and short circuit the entire system setup, therefore,
damaging the communication circuit of the HG4G/3G, HG2G-5F and non-isolated Communication Device (i.e. PLC).
To prevent such damage, choose a proper solution depending on your system setup.
• Use a separate earth ground from the external noise source device.
• The wire for grounding should be thick and short in order to direct the noise from the noise source device to the
earth ground.
• Use a separate power supply from the external noise source device.
• Insert an isolator on the communication line of the HG4G/3G, HG2G-5F and the non-isolated communication device
(i.e. PLC) to prevent damage.
●
Cautions for using the HG4G/3G, HG2G-5F connected to a personal computer
When connecting the HG4G/3G, HG2G-5F to a personal computer via the Serial Interface(COM1) or USB Interface,
the HG4G/3G, HG2G-5F or the personal computer may break down depending on the conditions of the personal
computer. Make sure of the following cautions, in order to prevent an accident.
• If the personal computer has a 3-pin power plug or power plug with a ground lead type. make sure to use a plug
socket including a ground input electrode or ground the earth lead, respectively.
• If the personal computer has a 2-pin power plug without ground lead, follow the procedure below when connect
the HG4G/3G, HG2G-5F to the personal computer.
(1) Pull out the power plug of the personal computer from the AC outlet.
(2) Connect the HG4G/3G, HG2G-5F to the personal computer.
(3) Insert the power plug of the personal computer into the AC outlet.
CAUTION
• Turn off the power supply before wiring.
• Make the wiring as short as possible and run all wires as far away as possible from high-voltage
and large-current cables. Follow all the procedures and precautions when wiring the HG4G/3G,
HG2G-5F.
• Separate the HG4G/3G, HG2G-5F power supply wiring from the power lines of I/O devices and
motor equipment.
• Ground the functional earth terminal to make sure of correct operation.
+
Power supply 24V DC (+24V)
-
Power supply 0V (0V)
Functional Earth (FE)
Type No.
HG4G/3G
HG2G-5F
Applicable cable
AWG18 to AWG22
AWG14 to AWG22
Recommended
Pressure Terminal
AI 0,34-8 TQ
AI 0,5-8 WH
AI 0,75-8 GY
AI 1-8 RD
AI-TWIN 2 x 0,5-8 WH
AI-TWIN 2 x 0,75-8 GY
AI-TWIN 2 x 1-8 RD
(Phoenix Contact)
AI 0,34-12 TQ
AI 0,5-12 WH
AI 0,75-12 GY
AI 1-12 RD
AI 1,5-12 BK
AI 2,5-12 BU
AI-TWIN 2 x 1,5-12 BK
(Phoenix Contact)
Tightening Torque
0.5 to 0.6 N
·
m
0.5 to 0.6 N
·
m
Summary of Contents for MICRO/I HG4G-CJT22 F-B Series
Page 1: ...B 1701 11 User s Manual ...
Page 26: ...Preface 25 WindO I NV4 User s Manual ...
Page 106: ...5 WindO I NV4 Common Operations and Settings 2 74 WindO I NV4 User s Manual ...
Page 254: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual ...
Page 362: ...5 Screen Restrictions 5 28 WindO I NV4 User s Manual ...
Page 402: ...3 Text 7 30 WindO I NV4 User s Manual ...
Page 574: ...9 Potentiometer 8 172 WindO I NV4 User s Manual ...
Page 1052: ...4 Using the Data 15 22 WindO I NV4 User s Manual ...
Page 1170: ...6 Important Notes 20 60 WindO I NV4 User s Manual ...
Page 1200: ...5 Restrictions 22 18 WindO I NV4 User s Manual ...
Page 1260: ...5 Editing User Accounts on the MICRO I 23 60 WindO I NV4 User s Manual ...
Page 1322: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual ...
Page 1414: ...4 E mail Function 28 66 WindO I NV4 User s Manual ...
Page 1554: ...3 Settings 34 14 WindO I NV4 User s Manual ...
Page 1642: ...2 Handling Problems 36 6 WindO I NV4 User s Manual ...
Page 1652: ...5 Text Alignment A 10 WindO I NV4 User s Manual ...
Page 1664: ...Index 12 WindO I NV4 User s Manual ...