WindO/I-NV4 User’s Manual
24-7
1 Communicating with the MICRO/I
24
Online F
unction
●
Using the online function for Ethernet communication
Select
Ethernet
under
Port
on the Communication Settings dialog box.
To download project data
Click
Download
in the Download dialog box to display the
Target IP Address
dialog box.
Specify the Ethernet settings (IP address, subnet mask, default gateway, and port number) for the MICRO/I.
Select the MICRO/I IP addresses and you can batch download project data to multiple MICRO/I.
It is also possible to change the Ethernet settings (IP address, subnet mask, default gateway, and port number) for
the MICRO/I to which you are downloading after project data is downloaded.
■
Target List
■
Add
Adds a download destination for project data to the
Target List
. Click this button to open the Target IP Address
dialog box. Using the Target IP Address dialog box, specify the Ethernet settings for the MICRO/I to which you are
downloading.
■
Edit
Changes the settings of the
Target List
.
Select a download destination from the
Target List
, and then click this button to open the Target IP Address dialog
box. Using the Target IP Address dialog box, change the Ethernet settings for the MICRO/I to which you are
downloading.
■
Delete
Deletes download destinations from the
Target List
.
■
Browse
Open IP Address Manager. Specify the IP address for the target MICRO/I with IP Address Manager. For details, refer to
“IP Address Manager” on page 24-11.
It is necessary to configure the MICRO/I according to the local network that is used.
On the
Communication Interface
tab in the Project Settings dialog box, configure the IP address, subnet
mask, default gateway, and port number, and clear the
Forbid Maintenance Communication
check box.
For details, refer to Chapter 4 “3.2 Communication Interface Tab” on page 4-35.
Target IP Address:
Displays the current IP address for the MICRO/I to download the project data to.
Target Port Number:
Displays the current port number for the MICRO/I to download the project data to.
Set IP Address:
Displays the IP address for the MICRO/I after downloading the project data.
Set Subnet Mask:
Displays the subnet mask for the MICRO/I after downloading the project data.
Set Default Gateway:
Displays the default gateway for the MICRO/I after downloading the project data.
Port Number:
Displays the port number for the MICRO/I after downloading the project data.
Even if the Ethernet settings of the MICRO/I are changed by using the Target IP Address dialog box when
downloading a project, the Ethernet settings in the editing project data are not changed.
Summary of Contents for MICRO/I HG4G-CJT22 F-B Series
Page 1: ...B 1701 11 User s Manual ...
Page 26: ...Preface 25 WindO I NV4 User s Manual ...
Page 106: ...5 WindO I NV4 Common Operations and Settings 2 74 WindO I NV4 User s Manual ...
Page 254: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual ...
Page 362: ...5 Screen Restrictions 5 28 WindO I NV4 User s Manual ...
Page 402: ...3 Text 7 30 WindO I NV4 User s Manual ...
Page 574: ...9 Potentiometer 8 172 WindO I NV4 User s Manual ...
Page 1052: ...4 Using the Data 15 22 WindO I NV4 User s Manual ...
Page 1170: ...6 Important Notes 20 60 WindO I NV4 User s Manual ...
Page 1200: ...5 Restrictions 22 18 WindO I NV4 User s Manual ...
Page 1260: ...5 Editing User Accounts on the MICRO I 23 60 WindO I NV4 User s Manual ...
Page 1322: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual ...
Page 1414: ...4 E mail Function 28 66 WindO I NV4 User s Manual ...
Page 1554: ...3 Settings 34 14 WindO I NV4 User s Manual ...
Page 1642: ...2 Handling Problems 36 6 WindO I NV4 User s Manual ...
Page 1652: ...5 Text Alignment A 10 WindO I NV4 User s Manual ...
Page 1664: ...Index 12 WindO I NV4 User s Manual ...