3 Drilling the Mounting Hole
3-8
KW2D Series Smart RFID Reader User’s Manual
3.1 Mounting Hole Layout
Drill a mounting hole in the panel with the dimensions shown in one of the following diagrams.
(Unit: mm)
3.2 Installation example
When mounting the KW2D Series Smart RFID Reader and IDEC push buttons on the same panel, the minimum pitch
differs depending on the mounting position and cable.
(Unit: mm)
3
Drilling the Mounting Hole
•
The numeric values given in the following diagram are a guide for the restrictions on wiring in the panel.
These numeric values will change depending on the cables that are used.
Use centers that take into consideration the usability of tags (KEYFOB type and card type) and other
obstructions.
•
If multiple KW2D Series Smart RFID Readers are installed close together, the radio waves will interfere
and tags cannot be read.
Ensure a space of 150 mm or more between the centers of neighboring front
units.
Mounting Position
Cable
CW Series
LW Series
LBW Series
*1
Left/Right
Not use
40
38
36
*2
Top
Not use
50
41
39
*3
Bottom
Use
120
115
115
ø22.3
R0.8 max
3.2
+0.2
0
+0.2
0
24
.1
+0.4
0
ø22.3
+0.2
0
Caution
*2
*3
*1
*1