Functions
HR9Z-B2202 8/2020
67
Application Function 9
Wiring of the inputs for sensors/devices with OSSD outputs
Characteristic
Value/Description
Typical applications
Monitoring of electro-sensitive protective
equipment such as type 4 light curtains as per
IEC 61496-1
Monitoring of RFID sensors
Type of outputs of sensor/device providing the input signal
for application function
OSSD (Output Signal Switching Device) outputs
S## terminals to be connected
S12-S13 for sensor/device A
S22-S23 for sensor/device B
Dynamization
No
Signal interlock monitoring
Between terminals S12 and S13
Between terminals S22 and S23
Synchronization of safety-related inputs
No
Summary of Contents for HR6S-S
Page 1: ...http www idec com HR6S S Safety Module Original instructions HR9Z B2202 ...
Page 8: ...8 HR9Z B2202 8 2020 ...
Page 14: ...14 HR9Z B2202 8 2020 ...
Page 20: ...Introduction 20 HR9Z B2202 8 2020 ...
Page 56: ...Installation 56 HR9Z B2202 8 2020 ...
Page 92: ...Accessories Service Maintenance and Disposal 92 HR9Z B2202 8 2020 ...