Functions
66
HR9Z-B2202 8/2020
Application Function 8
Synchronization:
Wiring of the inputs for sensors/devices with two PNP outputs
Characteristic
Value/Description
Typical applications
Monitoring of proximity switches
Type of outputs of sensor/device providing the input signal
for application function
Two PNP outputs
S## terminals to be connected
S12-S13 for sensor/device A
S22-S23 for sensor/device B
Dynamization
No
Signal interlock monitoring
Between terminals S12 and S13
Between terminals S22 and S23
Synchronized terminals
Synchronization time
S12 synchronized with S13
S12 and S13 have to be activated within 0.5 s.
S22 synchronized with S23
S22 and S23 have to be activated within 0.5 s.
Summary of Contents for HR6S-S
Page 1: ...http www idec com HR6S S Safety Module Original instructions HR9Z B2202 ...
Page 8: ...8 HR9Z B2202 8 2020 ...
Page 14: ...14 HR9Z B2202 8 2020 ...
Page 20: ...Introduction 20 HR9Z B2202 8 2020 ...
Page 56: ...Installation 56 HR9Z B2202 8 2020 ...
Page 92: ...Accessories Service Maintenance and Disposal 92 HR9Z B2202 8 2020 ...