28: AS-I
NTERFACE
M
ASTER
C
OMMUNICATION
« FC4A M
ICRO
S
MART
U
SER
’
S
M
ANUAL
»
28-35
SwitchNet Data I/O Port
SwitchNet control units can be used as slaves in the AS-Interface network and are available in ø16mm L6 series and
ø22mm HW series. Input signals to the
MicroSmart
AS-Interface master module are read to internal relays allocated to
each input point designated by a slave number and a DI number. Similarly, output signals from the
MicroSmart
AS-Inter-
face master module are written to internal relays allocated to each output point designated by a slave number and a DO
number. When programming a ladder diagram for the
MicroSmart
, use internal relays allocated to input signals and output
signals of SwitchNet control units.
L6 series and HW series SwitchNet control units have slightly different digital I/O data allocations.
L6 Series Digital I/O Data Allocation
Input data is sent from slaves to the AS-Interface master. Output data is sent from the AS-Interface master to slaves.
Notes:
SwitchNet L6 Series
Slave Unit
Used I/O
Input Data
(slave send data)
Output Data
(slave receive data)
DI3
DI2
DI1
DI0
DO3
DO2
DO1
DO0
Pushbutton
1 in
0
X1
1
1
*
—
—
—
Pilot light
1 out
0
0
1
1
*
—
—
X1
Illuminated pushbutton
1 in/1 out
0
X1
1
1
*
—
—
X1
Selector, Key selector, Lever: 2-position
1 in
0
X2
1
1
*
—
—
—
Selector, Key selector, Lever: 3-position
2 in
X3
X3
1
1
*
—
—
—
Illuminated selector: 2-position
1 in/1 out
0
X2
1
1
*
—
—
X1
Illuminated selector: 3-position
2 in/1 out
X3
X3
1
1
*
—
—
X1
1.
∗
The AS-Inter face master uses bit DO3 for addressing A/B
slaves.
2.
In the above table, bits marked with X1, X2, and X3 are used
for SwitchNet I/O data.
3. X1: When pushbutton is pressed, input data is 1 (on). When
not pressed, input data is 0 (off). When output data is 1 (on),
LED is on. When output data is 0 (off), LED is off.
4. X2: The input data from 2-position selector, key selector, and
illuminated selector switches and 2-position lever switches
depend on the operator position as shown below.
5.
X3: The input data from 3-position selector, key selector, and
illuminated selector switches and 3-position lever switches
depend on the operator position as shown below.
6.
Unused input bits DI3 and DI2 are 0 (off), and unused input
bits DI1 and DI0 are 1 (on). Slaves ignore unused output data
(—) sent from the master.
2-position Operator
Operator Position
Left/Down
Right/Up
DI2
0
1
Selector
Left
Right
Up
Down
Lever
3-position Operator
Operator Position
Left/Down
Center
Right/Up
DI3
0
0
1
DI2
1
0
0
Selector
Left
Right
Center
Up
Center
Down
Lever
•
Write_Parameter Command
•
Write_Parameter Settings
0
0
A4
A3
A2
A1
A0
1
Sel
P3
P2
P1
P0
PB
1
LED
Brightness
Settings
Remarks
Output
Selection
Control Data
P2
P1
P0
100%
1: DO0
0: DO1
1
1
Default
50%
0
1
25%
1
0
12.5%
0
0
Summary of Contents for FC4A-C10R2
Page 1: ...FC4A SERIES Micro Programmable Logic Controller User s Manual FC9Y B812 ...
Page 6: ...PREFACE 4 FC4A MICROSMART USER S MANUAL ...
Page 94: ...2 MODULE SPECIFICATIONS 2 74 FC4A MICROSMART USER S MANUAL ...
Page 184: ...6 ALLOCATION NUMBERS 6 20 FC4A MICROSMART USER S MANUAL ...
Page 218: ...8 ADVANCED INSTRUCTIONS 8 8 FC4A MICROSMART USER S MANUAL ...
Page 240: ...11 BINARY ARITHMETIC INSTRUCTIONS 11 8 FC4A MICROSMART USER S MANUAL ...
Page 244: ...12 BOOLEAN COMPUTATION INSTRUCTIONS 12 4 FC4A MICROSMART USER S MANUAL ...
Page 252: ...13 SHIFT ROTATE INSTRUCTIONS 13 8 FC4A MICROSMART USER S MANUAL ...
Page 274: ...15 WEEK PROGRAMMER INSTRUCTIONS 15 8 FC4A MICROSMART USER S MANUAL ...
Page 378: ...22 DUAL TEACHING TIMER INSTRUCTIONS 22 4 FC4A MICROSMART USER S MANUAL ...
Page 386: ...23 INTELLIGENT MODULE ACCESS INSTRUCTIONS 23 8 FC4A MICROSMART USER S MANUAL ...
Page 408: ...24 ANALOG I O CONTROL 24 22 FC4A MICROSMART USER S MANUAL ...
Page 426: ...26 COMPUTER LINK COMMUNICATION 26 6 FC4A MICROSMART USER S MANUAL ...