6
Installation and Servicing
Section 1 - General
Table 2 Performance Data - Central Heating
Boiler Input:
15 kW
18 kW
24 kW
30 kW
Min
Max
Min
Max
Min
Max
Min
Max
Net CV
kW
4.9
15.1
4.9
18.1
4.9
24.3
6.1
30.4
Gross CV
kW
5.4
16.6
5.4
20.1
5.4
27.0
6.7
33.7
Gas Consumption
m3/h
0.500
1.537
0.500
1.872
0.500
2.512
0.623
3.136
Boiler Output :
Non Condensing
70ºC Mean Water Temp.
kW
4.8
15.0
4.8
18.0
4.8
24.2
6.1
30.3
Condensing
40ºC Mean Water Temp.
kW
5.1
15.9
5.1
19.1
5.1
25.6
6.4
31.0
Seasonal Efficiency* SEDBUK 2005
91.2%
91.1%
91.2%
91.1%
Seasonal Efficiency* SEDBUK 2009/2012
89.4%
89.7%
89.7%
89.6%
NOx Classification
Class 6
Table 1 General Data
Gas consumption is calculated using a calorific value of
38.7 MJ/m
3
(1038 Btu/ft
3
) gross or 34.9 MJ/m
3
(935 Btu/ft
3
) nett
To obtain the gas consumption at a different calorific value:
a. For l/s - divide the gross heat input (kW) by the gross C.V. of
the gas (MJ/m
3
)
b. For Btu/h - multiply the gross heat input (kW) by 26.8
c. For ft
3
/h - divide the gross heat input (Btu/h) by the gross C.V.
of the gas (Btu/ft
3
)
d. For m
3
/h - multiply l/s by 3.6
C13 C33 C53
=
A room sealed appliance designed for
connection via ducts to a horizontal or vertical
terminal, which admits fresh air to the burner and
discharges the products of combustion to the
outside through orifices which, in this case, are
concentric. The fan is up stream of the combustion
chamber.
I
2H
= An appliance designed for use on 2nd family gas, Group H
only.
II
2H/3P
= An appliance designed for use on 2nd or 3rd family gases,
Group H or P.
* The value is used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating of dwellings.
The test data from which it has been calculated, has been certified by a notified body.
15 kW
18 kW
24 kW
30 kW
Gas Supply
2H-G20-20 mbar
Gas Supply Connection
15mm copper compression
Injector Size
mm
4.15
4.15
4.15
4.65
Flow Connection
Central Heating
22mm copper compression
Return Connection
Central Heating
22mm copper compression
Flue Terminal Diameter
mm
100
Average Flue Temp-Mass Flow Rate
56ºC - 6g/s
58ºC - 8g/s
63ºC - 10g/s 69ºC - 13g/s
CO
2
Content (± 0.7)
Max. CH
9.5%
9.3%
9.2%
9.6%
Min. CH
8.9%
8.3%
8.5%
8.7%
Maximum Working Pressure (Sealed Systems)
bar (psi)
2.5(36.3)
Electrical Supply
230 V ~ 50Hz
Power Consumption
W
70
75
94
102
Fuse Rating
External:3A Internal :T4A HRC L250 V
Water Content
Central Heating litre (gal)
1.2(0.26)
Packaged Weight
kg
31.3
Lift Weight
kg
27.3
Boiler Casing Size
Height mm
700
Width mm
395
Depth mm
278
BOILER SIZE
G.C. Applicance No
(Benchmark No.)
15
41-796-93
18
41-796-94
24
41-796-95
30
41-796-96