background image

28

EVOMOD

250 - 1000kW

Available in 250, 500, 750 and 1000 kW modules, the Evomod will achieve 
an output up to 1MW from a single unit solution together with a minimum 
footprint that enables the product to be installed where space is limited. Each 
module provides a maximum of 250 kW heat output and will modulate down 
through a sophisticated control system.

• Modules up to 3 high stacking

• Stainless steel heat exchanger

•  Built in module diagnostics, sequencing and 

remote indication

•  Plain text display for fast and easy use

•  Single flue outlet, system, gas and  

electrical connections

•  Up to 20:1 turndown: 1MW boiler can modulate 

down to just 46.7kW

• Easy access for servicing

•  Minimum footprint with easy site handling and 

standard doorway access allowing simplified 
plant replacement

•  NOx <40mg/kWh (Class 5) for maximum 

BREEAM points

• 2 year parts and labour warranty

•  Up to 108.5% net efficiency (fully condensing)

•  Single boiler control for all module options

FEATURES & BENEFITS

DOWNLOAD

THE APP

Summary of Contents for Logic HIU 50 Indirect

Page 1: ...PRODUCT GUIDE WE HAVE IT COVERED LOGIC HEAT INTERFACE UNITS HIUs...

Page 2: ...industry Your phone or tablet can let you appreciate our Condensing Boiler range in a new dimension The Ideal Commercial Eye app uses the latest technology to project 3D renders from the page of this...

Page 3: ...HIU 50 Direct MT 18 20 Logic HIU 50 Direct HT Metering Accessories 21 CF Echo II 21 CF UltramaxX V 21 Accessories Condensing Boiler range 23 Evomax 24 25 Evomax Cascade 26 Imax Xtra 27 Imax Xtra EL 2...

Page 4: ...e heat energy transfer units Designed for use in conjunction with centralised boilers district heating or central energy systems The function is to efficiently transfer heat from the plant room to the...

Page 5: ...All the Logic HIUs incorporate a spacer piece which can be easily removed and a heat meter fitted inside the unit This allows the energy used by each individual apartment to be recorded and charged a...

Page 6: ...hanges due to external influences such as outside temperature etc thereby ensuring that the unit and the system operate at maximum efficiency Pump bypass protection in case of complete radiator TRV sh...

Page 7: ...S STANDARD ACCESSORIES The temperature setting operates on the principle of set point regulation and can be fixed within application limits Heating Set Point 25 to 75 C Nom heating exchanger net outpu...

Page 8: ...1 Kv 2 63 m h UPS 15 60 pump settings D Flowrate l s 50 10 1 0 5 20 30 2 3 5 Pressure loss kPa Kv 2 03 m h F H HEATING CHS HR HF DHW heat exchanger 0 04 0 06 0 08 0 1 0 2 0 3 0 4 0 5 0 04 0 06 0 08 0...

Page 9: ...t exchanger Flowrate l s 10 1 0 5 2 3 5 Pressure lo HR HF CHS HR HF Primary Flow Rate I h Primary flow temperatures 1 500 1 400 1 200 1 000 800 600 400 200 0 0 100 200 300 400 500 600 700 800 900 1 00...

Page 10: ...ater Automatically compensate for changes due to external influences such as outside temperature etc thereby ensuring that the unit and the system operate at maximum efficiency Convertible to underflo...

Page 11: ...STANDARD ACCESSORIES The temperature setting operates on the principle of set point regulation and can be fixed within application limits Heating Set Point 25 to 75 C Nom heating exchanger net output...

Page 12: ...0 pump settings D Flowrate l s 50 10 1 0 5 20 30 2 3 5 Pressure loss kPa Kv 2 03 m h F H HEATING DHW heat exchanger 0 04 0 06 0 08 0 1 0 2 0 3 0 4 0 5 0 04 0 06 0 08 0 1 0 2 0 3 0 4 0 5 Flowrate l s 5...

Page 13: ...atures 55 C 65 C 75 C 85 C HYDRAULIC CHARACTERISTICS HEATING SECONDARY SIDE DHW heat exchanger 0 04 0 06 0 08 0 1 0 2 0 3 0 4 0 5 0 04 0 06 0 08 0 1 0 2 0 3 0 4 0 5 Flowrate l s 50 10 1 0 5 20 30 2 3...

Page 14: ...rt pump as standard including a pump bypass loop in case of complete radiator TRV shutdown Compact and lightweight Fully insulated EPP front cover Includes differential pressure control valve DPCV sup...

Page 15: ...CONSTRUCTION INCLUDED AS STANDARD The temperature setting operates on the principle of set point regulation and can be fixed within application limits HEATING The DHW function takes priority over the...

Page 16: ...6 Flowrate l s Pressure loss kPa Kv 2 12 m h 3 2 1 Flowrate l s 50 10 1 0 5 20 30 2 3 5 Pressure loss kPa Kv 2 20 m h 0 10 20 30 40 50 60 Flowrate l s Pressure loss kPa Kv 2 12 m h 3 2 1 SATK 20203 me...

Page 17: ...Primary Flow Rate I h Primary flow temperatures 1 500 1 400 1 200 1 000 800 600 400 200 0 0 100 200 300 400 500 600 700 800 900 1 000 1 100 Domestic Hot Water Flow Rate 48 C l h 55 C 60 C 65 C 70 C 7...

Page 18: ...ulated EPP front cover Includes differential pressure control valve DPCV supplied and fitted to the base of the unit Ability to pre heating of the DHW exchanger FEATURES BENEFITS The Logic heat interf...

Page 19: ...nless steel CONSTRUCTION INCLUDED AS STANDARD The temperature setting operates on the principle of set point regulation and can be fixed within application limits HEATING The DHW function takes priori...

Page 20: ...200 1 000 800 600 55 C 60 C 65 C 70 C 75 C 80 C 85 C rimary Flow Rate I h Primary flow temperatures 1 500 1 400 1 200 1 000 800 600 55 C 60 C 65 C 70 C 75 C 80 C 85 C Primary flow temperatures 0 0 0...

Page 21: ...ring differential pressure test points required ACCESSORIES MODEL METER SALES CODE Logic HIU 75 Indirect Factory fitted CF Echo 11 MBus 1 211346 Logic HIU 50 Indirect 211347 Logic HIU 50 Direct MT 211...

Page 22: ...CONDENSING COMMERCIAL BOILERS...

Page 23: ...1 turndown Compact one width height for easy siting Simple controls interface with large backlit display Comprehensive range of flue fixing and control options Designed for easy installation commissi...

Page 24: ...e kits are available for use with in line kits if required BACK TO BACK KITS Kits include all the in line contents plus the required special frame kits for such compact installations Both types of kit...

Page 25: ...header the boiler the flow and return flexible connections which reduce installation time Delivered with header kit connection pipe assembly non return valves pipe work connector all isolation valves...

Page 26: ...hanger In built commissioning and fault diagnostics Volt free contacts and BMS operation standard Meets Building Regulations Part L2 Compact size small footprint High 5 1 turndown Up to 107 5 net effi...

Page 27: ...tallations Simple control interface with large backlit display Volt free contacts 0 10V BMS operation standard Robust aluminium silicon alloy heat exchanger Suitable for single or multiple installatio...

Page 28: ...less steel heat exchanger Built in module diagnostics sequencing and remote indication Plain text display for fast and easy use Single flue outlet system gas and electrical connections Up to 20 1 turn...

Page 29: ...tions Up to 109 3 part load efficiency Designed to operate up to 40 C T providing minimum flow rates are achieved Dedicated low temp return Stainless steel heat exchanger Natural gas LPG oil and dual...

Page 30: ...EVOMAX Wall Hung Aluminium Alloy Heat Exchanger 30 150 kW 30 80kW LPG IMAX XTRA Floor Standing Aluminium Alloy Heat Exchanger 80 280 kW EVOMOD Floor Standing Stainless Steel Heat Exchanger Modular 250...

Page 31: ...IU 50 DIRECT MEDIUM TEMP MT LOGIC HIU 50 DIRECT HIGH TEMP HT The Ideal Heat Interface Units are heat energy transfer units Designed for use in conjunction with centralised boilers district heating or...

Page 32: ...32...

Page 33: ...33...

Page 34: ......

Page 35: ...ed by a dedicated national service team delivering help and advice to you and your customers throughout the year SALES Tel 0844 5436060 Fax 0844 5436181 TECHNICAL Tel 01482 440237 Fax 01482 498621 com...

Page 36: ...vement in design and performance of its products and reserves the right to vary specification without notice Statutory rights of the consumer are not affected PLEASE NOTE The information in this broch...

Reviews: