users guide

Your Ideal users guide

See reverse for                      installation & servicing guide

When replacing any part on this appliance, use only spare parts that you can be 
assured conform to the safety and performance specification that we require. Do not 
use reconditioned or copy parts that have not been clearly authorised by Ideal Boilers.

plus 

III

Models F95, F145, F190
& F235, F285, F330

plus 

III

Summary of Contents for imax plus iii F145

Page 1: ...ing any part on this appliance use only spare parts that you can be assured conform to the safety and performance specification that we require Do not use reconditioned or copy parts that have not bee...

Page 2: ...d utilizing today s heating technology and in compliance with the current safety regulations However following an improper use dangers could arise for the safety and life of the user or of other peopl...

Page 3: ...O BE HANDED OVER TO THE USER 5 SAFETY WARNINGS WARNING The installation adjustment and servicing of this appliance must be carried out by a competent person and installed in accordance with the curren...

Page 4: ...T I HEAT CIRCUIT II SOLAR MF Time programs CIRCL TIME HOTW PROGR HOTW PROGR I etc Expert INSTALLATION HOT WATER HEAT CIRCUIT I HEAT CIRCUIT II SOLAR MF INSTALLATION Change the parameter value with the...

Page 5: ...re shown the factory set parameters For additional information refer to the E8 instruction manual supplied with the boiler Press to enter Level ENGLISH Set new value TIME YEAR MONTH SETUP DAY 1 1 1 1...

Page 6: ...ART DAY STOP Press to return Open the flap DISPLAY GENERAL Elapsed 2 sec On display is shown the sub LEVEL Turn clockwise Turn clockwise Set new value Set new value Press to enter Level Press to enter...

Page 7: ...year XXXX MONTH START Set current holliday start month 01 12 DAY START Set current holliday start day 01 31 YEAR STOP Set current holliday end year XXXX MONTH STOP Set current holliday end year 12 31...

Page 8: ...T PRG 00 RETURN Press to exit OTHER PARAMETRES Open the flap Turn anticlokwise Elapsed 2 sec On display is shown the sub LEVEL Turn anticlokwise Press to enter Level Turn clockwise Turn clockwise Turn...

Page 9: ...it 1 F3 Upper buffer storage temperature F5 Flow temperature heating circuit 2 F6 Upper hot water temperature F8 Boiler Header temperature F9 Outside temperature F11 Flow temperature heating circuit 1...

Page 10: ...clockwise Turn clockwise Turn clockwise Press to enter Level Press to enter Level Press to enter Level Press to enter Level Turn clockwise Turn clockwise Turn clockwise Turn clockwise Turn clockwise T...

Page 11: ...DHW Hot water temperature value T DHW L Hot water temperature in infeed area T CIRC Recirculating temperature RETURN T ROOM DES A Current value for set room temperature T ROOM Room temperature HUMIDIT...

Page 12: ...to enter Level Set the value Turn clockwise Set the value Turn clockwise Set the value Turn clockwise Press to exit Turn clockwise Set the value Turn clockwise Set the value Turn clockwise Set the va...

Page 13: ...t T ROOM DES 1 Room temperature setting in first enable time 20 5 40 T ROOM DES 2 Room temperature setting in second enable time 20 5 40 T ROOM DES 3 Room temperature setting in third enable time 20 5...

Page 14: ...ating program for second controller heating circuit Active only with parameter 1 x HW 00 By leaving the hour blank_ _ _ _ the heating period is bypassed HTG PROG 1 Turn clockwise CIRCL TIME 1 HTG PROG...

Page 15: ...Set the value Turn clockwise Set the value Turn clockwise Set the value Press to exit Set the value Set the value Set the value Set the value Set the value Set the value Set the value Set the value S...

Page 16: ...el Set the Value Set the Value Set the Value Set the Value Set the Value Set the Value Turn clockwise Turn clockwise Turn clockwise Turn clockwise Turn clockwise Turn clockwise Turn clockwise Turn clo...

Page 17: ...Views the FA parameters of the boiler board module 7 Views the FA parameters of the boiler board module 8 Press to enter Level Turn clockwise Open the flap EXPERT HS Turn clockwise Turn clockwise Turn...

Page 18: ...in CAP MODULE After restarting the controller searches the bus systems 0 1000 NEW CONFIG If the BUS configuration was modified the automatic 00 01 MIN MOD CASC When the casacade is started the number...

Page 19: ...election 0 00 04 PUMP MODE Pump operating mode 02 00 03 MIXER OPEN Open mixer dynamic 18 5 25 MIXER CLOSE Close mixer dynamic 12 5 25 MAX T FLOW max flow temperature setting 80 20 110 MIN T FLOW min f...

Page 20: ...ert area Heating circuit I II HC FUNC 02 For additional informations refer to the E8 instruction manual supplied with the boiler Swimming pool temperature setting Only after function selection User Ar...

Page 21: ...E70 E8 F11 Flow temperature sensor heating circuit 1 E71 E8 F1 Lower storage temperature sensor Buffer E72 E8 F3 Higher storage temperature sensor Buffer E75 E8 F9 Outer temperature sensor AF E76 E8 F...

Page 22: ...USER 1X ACQUA C T AC 1 NOM T AC 2 NOM T AC 3 NOM MODE T ROOM DES 2 T ROOM DES 3 T REDUCED T ABSENCE T LIMIT DAY T LIMIT N HEAT SLOPE RETURN Compensation slope outer temperature SOLAR M F INSTAL Elapse...

Page 23: ...it is therefore necessary to always verify the boiler model on which it is use in order to select the most convenient setting Open the Flap Turn clockwise HTG PROG 1 CIRCL TIME 1 HTG PROG 2 1 HTG PRO...

Page 24: ...x 01482 448858 Registration No London 322 137 Ideal Stelrad Group pursues a policy of continuing improvement in the design and performance of its products The right is therefore reserved to vary speci...