IDEAL AP60 PRO
IDEAL AP80 PRO
www.ideal
healthstore.com
EN Operating Instructions
Air Purifier
Page 1: ...IDEAL AP60 PRO IDEAL AP80 PRO www idealhealthstore com EN Operating Instructions Air Purifier...
Page 2: ...Fan speeds 33 Timer function 33 Quiet function 34 Air quality indicator 34 Filter replacement indicator 34 Daylight sensor 34 IR receiver 34 Air quality sensor 34 Remote control when using for the fi...
Page 3: ...l trip over it Do not place the power cable under strain Disconnect the plug from the wall socket for cleaning purposes and whenever the device is not in use for a significant period of time Do not to...
Page 4: ...life and health Do not use the unit near a fire alarm If the outlet air is blowing towards a fire alarm the alarm may respond late or not at all Caution Risk of injury due to electric shock Always dis...
Page 5: ...be replaced Air purification in 5 speed settings 3 stage air purification system Pre filter HEPA filter coated with activated carbon 360 filter Pre filter HEPA active carbon Easy maintenance and repl...
Page 6: ...wall Keep the device away from areas subjected to draft wind Make sure that furniture fabrics or other objects do not come in contact with the air intake outlet or block them Place the device on a st...
Page 7: ...activated carbon Insert the filter cartridge with the three tabs in the notches provided and lock in position by turning clockwise 12 Hold the filter cartridge with both hands using the recessed grip...
Page 8: ...31 Air outlet grill Overview and description of parts Front panel Power cable Filter cartridge Control panel Air intake ducts...
Page 9: ...ity sensor B Fan speed button C Timer button Note The air quality sensor L is recalibrated the first time you switch it on A and after being disconnected from the mains power supply Once the air quali...
Page 10: ...e the air purifier is switched on activates the switch off timer after the set time the air purifier switches off Switch the air purifier on on off button A Press the timer button C to activate the ti...
Page 11: ...er is approx 1 year depending on operation and purification activities If odours are no longer being filtered out or if the filter produces unpleasant odours then the filter cartridge needs to be repl...
Page 12: ...rol and the air purifier The air purifier should not be placed in direct sunlight This could impair the infrared sensor Locations where fluorescent tubes are flickering because they are defective or o...
Page 13: ...h these with suitable gloves Keep batteries out of the reach of children Take the batteries out of the device if you are not going to be using it for a significant period of time Replacing the battery...
Page 14: ...isconnecting the air purifier from the mains or by pressing and holding down the on off button A on the device Note When you operate the remote control the air quality indicator E lights up for approx...
Page 15: ...e tabs in the notches provided and lock in position by turning clockwise 7 Hook in the front panel at the bottom first 8 then pivot upwards and press shut 9 Connect the power cable to the device first...
Page 16: ...ndicator E flashes blue The WLAN is disabled when the air quality indicator E flashes white Resetting the WLAN The air purifier is disconnected from the power supply Press and hold down the Quiet butt...
Page 17: ...nd the interior of the air purifier with a vacuum cleaner Clean the filter cartridge s pre filter with a vacuum cleaner To do this remove the filter cartridge Changing the filter page 38 Do not use an...
Page 18: ...is clicked in place with all 3 tabs and is fully locked padlock icon page 30 The buttons on the air purifier do not work The buttons on the remote control do not work Has the locking function been act...
Page 19: ...s dirty Clean the openings for the air quality sensor L dust sensor M page 32 the air intake ducts and the interior of the air purifier where the filter cartridge is located with a vacuum cleaner The...
Page 20: ...fan speed Use the fan speed button B page 33 to set a lower fan speed G page 33 In bright environments the indicators on the air purifier control panel are too dark Is the daylight sensor dirty Clean...
Page 21: ...668 mm Weight 15 kg Volume at turbofan speed max 56 6 dB A Volume in Quiet mode min 16 5 dB A For a room height of 2 50 m IDEAL AP80 PRO Power supply 200 240V 50 60Hz 100 120V 50 60Hz Power consumptio...
Page 22: ...mply with the rating plate data Storage We recommend storing the air purifier in its original packaging in a cool dry place Pack and store the filter cartridge airtight to protect the activated carbon...
Page 23: ...46 Quality management system according to DIN EN ISO 9001 2015 Environmental management system according to DIN EN ISO 14001 2015 Energy management system according to DIN EN ISO 50001 2018...
Page 24: ...rewith we declare that GS IDENT No UL IDENT No IDEAL AP60 PRO Made in Germany 11874101 10874101 IDEAL AP80 PRO Made in Germany 11874102 10874102 complies with the following provisons applying to it 20...
Page 25: ......