Chapter 2
Test Setup Procedures
Saving in TIA/EIA 606A Format
1.
Once the Enable 606A selection process has been completed, press AUTOTEST to
begin.
Note: LANTEK uses the Standards format to apply identification to the cables and
their infrastructure relationship.
2.
At completion of the Autotest activity, select one of three cable parameters (Drop,
Backbone or Backbone Pair) to set the cable name for saving the results. Cable
naming can be completed using the Auto Increment feature or manually.
Figure 2-19: TIA 606A Cable Parameter Screens
3.
Press ENTER to save the cable name and results or ESCAPE to exit.
4.
If Enable 606A is selected in the Autotest Preference, then a 606A Standards Cable
parameter can be edited by pressing F1 or selecting the Cable ID on the DH Ready
Screen.
DUALMODE
The DUALmode
TM
feature on the LANTEK is designed to provide both Permanent Link
and Channel Link test results in about the same time that it would take to do each
Autotest separately. For Category 6, that means both Channel and Permanent Link
results are obtained and stored in about 20 seconds.
Based on the patent-pending technique that LANTEK uses to produce Permanent Link
results, the dual mode adapters physically resemble Channel Adapters and patchcords
that gather both phase and magnitude data for the full channel. The LANTEK Cable
Certifier process removes the patchcords losses and signal reflections to produce
Permanent Link results. The DUALmode function saves the results in two separate
records.
Other significant tests can be performed under the DUALmode process. For example,
consider the case where you, the installer, have a job to install a Category 6 class
system in a government installation in a country that uses an ISO-based National
Standard. You use cable and connectivity manufactured by a US-based company. The
government may require the installer to certify the ISO-based CLASS E standard but
the US Company may require certification to the TIA 568 Category 6 Standard in order
to issue a warranty. Previously, this might have required running both ISO and TIA
certifications and passing the increased costs to your client, the buyer. But with
DUALmode, certifications to ISO CLASS E Permanent Link and TIA 568B Category 6
can be performed at the same time with no more effort than running only one test.