background image

 
 
 

PROGRAMMING-INSTRUCTION

 

 
 
 

Refrigerated Air Pans 

 

 

BAKERY  

For flat presentation, flush mounted, 

Loading height: max. 60mm  

BAKERY H 

Flat presentation with raised air tower for larger 

products like Pastries, Cakes, Delicacies, e.g. 

UKW  

Functional Air Pan for the use of adjustable base decks 

 or Containers GN 1/1 up to 150mm depth 

 

self-contained or for remote refrigeration

 

 
 
 

For authorized refrigeration companies and qualified service personnel!

 

 
 

 

 

WARRANTY IS NOT GUARANTEED IF THE FOLLOWING  

INSTRUCTIONS ARE NEGLECTED! 

- Siphon -

Gastro norm

pan

Condensing unit

moveable

lift up Evaporator

Control unit / box

(Display can mount up to 6 
feet away from control box)

Base decks - adjustable in height

inner base - removable

Summary of Contents for BAKERY

Page 1: ...the use of adjustable base decks or Containers GN 1 1 up to 150mm depth self contained or for remote refrigeration For authorized refrigeration companies and qualified service personnel WARRANTY IS NOT GUARANTEED IF THE FOLLOWING INSTRUCTIONS ARE NEGLECTED Siphon Gastro norm pan Condensing unit moveable lift up Evaporator Control unit box Display can mount up to 6 feet away from control box Base d...

Page 2: ...s required for commissioning networked systems ENTERING A PASSWORD By selecting code word you can enter a password required for parameterisation Once the password has been entered the name of the first group of parameters is displayed alarms Now using the buttons UP and DOWN you can select any of the parameter groups quickly PRE DESIGNED PARAMETER SETS With this parameter by selecting code word an...

Page 3: ...ns the actual temperature is displayed again This is the standard setting method Please note that the setpoint can only be changed within the set setpoint limits Access to USER setting To activate parameterisation mode press buttons UP and DOWN at the same time After approx 3 seconds the code word will be displayed Press UP or DOWN to switch between code words and To offer an easy handling of the ...

Page 4: ...o defrost 1 compressor of air only 2 electrical 3 with hot gas 1 1 1 1 Stop at defrosting temperature 0 30 0 C 7 0 C 7 0 C 7 0 C 7 0 C Fan control circuit 1 Para meter Description of function Setting range UKW BAKERY BAKERY H BAKERY S Fan speed control mode Set1 0 100 65 0 45 0 55 0 55 0 Fan speed defrosting Set1 0 100 80 0 45 0 80 0 80 0 Temperature sensors Para meter Description of function Sett...