5.5
System view
Once the connection to the instrument is made, the software will retrieve the current
card configuration and will give a system overview as depicted below which shows an
example of 96 laser ports.
5.5.1
Tree view
Tree view is located on the left hand side of the GUI and gives a quick overview on
installed laser ports. It also allows switching to chassis and slot level view by clicking
on the according chassis or Slot.
5.5.2
Spectral viewer
This diagram gives a quick overview of the current laser configuration. Each bar
represents one laser port. The height of represents the laser power. Right click on the
diagram for options for zooming and viewer manipulation.
Laser ports that are turned off are not displayed.
5.5.3
Status table “Current Status”
The status table is located displays the current status of all optical parameters for all
lasers. It is continuously updated. Use the scroll control on the right hand side to
browse through all available lasers.
5.5.4
Set table “Set new Status”
The right hand side of the table allows setting all optical parameters and the state of
the output. Dial in the required values and press the according “Set” Button to
Summary of Contents for CoBrite DX1