To program range mode:
1.
Type
2
then
Enter
to enable range mode.
Range mode is disabled by default. When it is enabled the message
Range Mode: On
will appear at the top of
the user menu.
2.
User 1 is the start user, i.e. the lower bound of the range. To program the start user:
-
Type
1, Enter
to edit a user.
-
Type
1, Enter
to select user 1.
-
Assign the lowest Transmitter ID in the range to this user (by pressing a button on the transmitter, or
typing in the Transmitter ID).
-
Pres
Enter
.
3.
User 2 is the end user, i.e. the upper bound of the range. To program the end user:
-
Type
1, Enter
to edit a user.
-
Type
2, Enter
to select user 2.
-
Assign the highest Transmitter ID in the range to this user (by pressing a button on the transmitter, or
typing in the Transmitter ID).
-
Press
Enter
.
Quick User Programming
This feature is only available when the receiver mode is set to
Individual User Mode
.
To add new remotes:
1.
Hold down the
PRG
button (on the bottom right hand side of the unit)
2.
Press any button on the new transmitter, and check that the
RF
light flashes when doing so.
3.
The user has now been added at the next available slot in the user list.
Site Code Menu
This menu is only available when the receiver mode is set to
Custom Site Code Mode
.
To enter the site code menu, type the shortcut:
Esc, F, Enter
In this mode the wireless receiver will accept all transmitters with the programmed site code.
Adding/Editing the Site Code
1.
Type
1, Enter
to edit the site code.
2.
Type the new site code then press
Enter
.
3.
Press
Esc
to finish programming.
Button Menu
To enter the button menu, type the shortcut:
Esc, D, Enter
For each button or combination of buttons, type the button number and press
Enter
to select from:
⦁
Off
: Pressing the button has no effect.
⦁
Wiegand Port 1 (P1/P2)
: Send credential data on Wiegand port 1 (P1 and P2).
⦁
Wiegand Port 2 (P3/P4)
: Send credential data on Wiegand port 2 (P3 and P4).
⦁
Relay
: Activate the relay output for 2 seconds.
⦁
P1 / P2 / P3 / P4
: Activate the selected programmable output for 2 seconds.
RF-RCVR-433 | Wireless 433MHz Receiver | Installation Manual
9