background image

PRT-RDM2-DIN-485

Protege DIN Rail 2 Door Reader Expander

Installation Manual

Summary of Contents for PRT-RDM2-DIN-485

Page 1: ...PRT RDM2 DIN 485 Protege DIN Rail 2 Door Reader Expander Installation Manual...

Page 2: ...hanical for any purpose without the express written permission of Integrated Control Technology Limited Designed and manufactured by Integrated Control Technology Limited Protege and the Protege Logo...

Page 3: ...ection 14 Multiple Wiegand Reader Connection 15 Magnetic Reader Connection 16 Door Contact Connection 16 Door Lock Connection 17 Inputs 18 Trouble Inputs 19 Door Trouble Inputs 19 Outputs 20 Lock Outp...

Page 4: ...European Standards 31 UK Conformity Assessment Mark 33 UL and ULC Installation Requirements 34 UL ULC Installation Cabinet Options 34 CAN ULC S319 34 UL294 34 FCC Compliance Statements 36 Industry Can...

Page 5: ...distance of up to 900M 3000ft Further span can be achieved with the use of a network repeater module The current features of the reader expander include 4 Wiegand reader mode for 2 Entry Exit doors p...

Page 6: ...r Alarm Systems CAN ULC S302 Installation and Classification of Burglar Alarm Systems for Financial and Commercial Premises Safes and Vaults CAN ULC S561 Installation and Services for Fire Signal Rece...

Page 7: ...r wire or wires of the appropriate gauge Earth Ground Connection The DIN rail enclosure and the DIN rail modules must be grounded to a suitable single point earth ground connection in the installation...

Page 8: ...Rail Enclosure DIN Rail Enclosure Module Network RS 485 N N NA and NB DIN Rail Ground Connections multiple cabinets in different rooms sectors or buildings The Dialer s Earth Ground Connection applies...

Page 9: ...talled in an electrical room communication equipment room secure cabinet or in an accessible area of the ceiling 1 Position the DIN rail module with the labeling in the correct orientation 2 Hook the...

Page 10: ...ing registration with controller Module communication activity Number of Flashes For further details refer to the Error Code Display section in the installation manual Address Too High Address in Use...

Page 11: ...age to all devices on the RS 485 network Warning The 12V N and N communication input must be supplied from only one point Connections from more than one 12V supply may cause failure or damage to the u...

Page 12: ...o any shield used for isolated communication The reader and cable shield wires must be joined at the reader pigtail splice Do not join the shield and black wires at the reading device Do not terminate...

Page 13: ...providing an entry exit configuration Shield wires connected at the splice Reader shield is not terminated inside the reader Shield is frame grounded at one point ENTRY V V C BZ L2 L1 D1 D0 NB NA 1 2...

Page 14: ...rounded at one point RED BLACK GREEN WHITE ORANGE BROWN BLUE YELLOW VIOLET Shielded Cable SHIELD Dual LED operation allows the signaling of both LEDs independently using the LED control lines and is i...

Page 15: ...xed into the alternate reader port will operate as the exit reader and the normal reader connection operates as the entry reader Reader shield is not terminated inside the reader Data V V C BZ L2 L1 D...

Page 16: ...e supply voltage is correct and if required insert the inline 5 volt regulator as shown in the diagram above Door Contact Connection The module allows the connection of up to 4 contacts for monitoring...

Page 17: ...can be used to switch electric locks Door Lock Outputs When using a door with an entry and exit reader on separate reader ports the lock output should be connected to LOCK 1 and enable the Swap Lock...

Page 18: ...d CAN ULC S319 standalone access control When using an input with the EOL resistor configuration the controller generates an alarm condition when the state of an input changes between open and closed...

Page 19: ...Dxxx 12 Reader 1 Tamper System Tamper System RDxxx 13 Reader 2 Tamper System Tamper System RDxxx 14 Door 1 Lockout Too Many Attempts Access RDxxx 15 Door 2 Lockout Too Many Attempts Access RDxxx 16 Mo...

Page 20: ...this amount will damage the output Standard Outputs 3 To 8 The outputs 3 4 5 6 7 and 8 on the reader expander are open collector outputs and switch to a ground connection The outputs have a default pr...

Page 21: ...nted and access is denied or the unit is operating offline The following table shows the beeper modes of operation Function Description 2 Beeps Access Granted The lock will activate and allow access t...

Page 22: ...product Refer to the Protege system controller installation manual for address programming details The controller has a set limit on the number of modules of each type that it can support When adding...

Page 23: ...peration Fault Indicator The fault indicator is lit any time the module is operating in non standard mode If the fault indicator is flashing the module requires a firmware update or is in firmware upd...

Page 24: ...enever an input on the module is programmed with an input type and area the input status will be displayed on the front panel indicator corresponding to the physical input number This allows for easy...

Page 25: ...feature in the controller s web interface 3 Address Too High The module address is above the maximum number available on the system controller To clear this error change the address to one within the...

Page 26: ...iagram The diagram shown below outlines the essential details needed to help ensure the correct installation of the reader expander PRT RDM2 DIN 485 Protege DIN Rail 2 Door Reader Expander Installatio...

Page 27: ...ls needed to help ensure correct installation and mounting All measurements are shown in millimeters 90 00 156 80 44 68 Front 139 18 72 00 2x 4 67 Screw Hole 17 03 42 40 42 40 156 80 35 40 Back PRT RD...

Page 28: ...ess Modes All Users First 10 Users plus 150 Card Cache No Users Readers Reader Configurations 2 reader ports that can be independently configured for either Wiegand up to 1024 bits configurable or RS...

Page 29: ...chnologies they must be connected on separate ports The ICT implementation of OSDP conforms to a subset of the OSDP functionality For specifications and reader configuration refer to Application Note...

Page 30: ...eneral Product Statement The RCM compliance label indicates that the supplier of the device asserts that it complies with all applicable standards PRT RDM2 DIN 485 Protege DIN Rail 2 Door Reader Expan...

Page 31: ...your local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accordance with your national legislation For b...

Page 32: ...ne input for masking To comply with EN 50131 1 Do not fit more than 10 unpowered detectors per input Do not fit more than one non latching powered detector per input Do not mix unpowered detectors and...

Page 33: ...General Product Statement The UKCA Compliance Label indicates that the supplier of the device asserts that it complies with all applicable standards PRT RDM2 DIN 485 Protege DIN Rail 2 Door Reader Ex...

Page 34: ...d grounded cable All readers must be connected with shielded grounded cable A bell or visual indicator used as an arming acknowledgment signal must be listed to a ULC security signaling or fire standa...

Page 35: ...10B or UL10C Must be installed with UL 1034 listed electronic locks for UL installations AC power on shall be indicated by an external panel mount LED Lumex SSI LXH312GD 150 and fitted into a dedicate...

Page 36: ...s device may not cause harmful interference This device must accept any interference received including interference that may cause undesired operation NOTE THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHAN...

Page 37: ...s class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada CAN ICES 3 A NMB 3 A PRT RDM2 DIN 485 Protege DIN Rail 2 Door...

Page 38: ...e liable under any circumstances to any party in respect of decisions or actions they may make as a result of using this information In accordance with the ICT policy of enhanced development design an...

Page 39: ...eserved Disclaimer Whilst every effort has been made to ensure accuracy in the representation of this product neither Integrated Control Technology Ltd nor its employees shall be liable under any circ...