background image

PRT-F2F8-DIN

Protege Half DIN Rail 8 Port F/2F Reader
Expander

Installation Manual

Summary of Contents for PRT-F2F8-DIN

Page 1: ...PRT F2F8 DIN Protege Half DIN Rail 8 Port F 2F Reader Expander Installation Manual...

Page 2: ...ical for any purpose without the express written permission of Integrated Control Technology Limited Designed and manufactured by Integrated Control Technology Limited Protege and the Protege Logo are...

Page 3: ...Trouble Inputs 12 Outputs 13 Address Configuration 14 LED Indicators 15 Status Indicator 15 Fault Indicator 15 Power Indicator 15 Error Code Indication 16 Error Code Display 16 Mechanical Diagram 17 M...

Page 4: ...ules can be connected to the Protege system in any combination to the network over a distance of up to 900M 3000ft Further span can be achieved with the use of a network repeater module The current fe...

Page 5: ...ts This equipment is to be installed in accordance with The product installation instructions The Local Authority Having Jurisdiction AHJ PRT F2F8 DIN Protege Half DIN Rail 8 Port F 2F Reader Expander...

Page 6: ...ire or wires of the appropriate gauge Earth Ground Connection The DIN rail enclosure and the DIN rail modules must be grounded to a suitable single point earth ground connection in the installation A...

Page 7: ...l Enclosure DIN Rail Enclosure Module Network RS 485 N N NA and NB DIN Rail Ground Connections multiple cabinets in different rooms sectors or buildings The Dialer s Earth Ground Connection applies to...

Page 8: ...b clip under the edge of the DIN rail 3 Push the DIN rail module against the mount until the tab clips over the rail Removal A Protege DIN rail module can be removed from the DIN rail mount using the...

Page 9: ...e to all devices on the RS 485 network Warning The 12V N and N communication input must be supplied from only one point Connections from more than one 12V supply may cause failure or damage to the uni...

Page 10: ...connected at one end of the cable in the metallic enclosure frame grounded Do not connect the cable shield to an AUX 0V or V connection on the module Do not connect the cable shield to any shield use...

Page 11: ...a door lock circuit relay is achieved by connection between the 12VDC V and the DO DOOR terminals on a port of the reader expander Door Lock Outputs V V DOOR DATA Electric Locking Device Power Supply...

Page 12: ...RDxxx 08 Reader 8 Tamper Missing Module Tamper System RDxxx 09 Auxillary Fuse Supply Fault Port 1 2 Power General RDxxx 10 Auxillary Fuse Supply Fault Port 3 4 Power General RDxxx 11 Auxillary Fuse S...

Page 13: ...er expander has 8 programmable outputs These outputs are used for activation of door lock relay circuits 200mA max sink 24VDC max PRT F2F8 DIN Protege Half DIN Rail 8 Port F 2F Reader Expander Install...

Page 14: ...oduct Refer to the Protege system controller installation manual for address programming details The controller has a set limit on the number of modules of each type that it can support When adding an...

Page 15: ...date or the identification time period expiring the module will return to normal operation Fault Indicator The fault indicator is lit any time the module is operating in non standard mode If the fault...

Page 16: ...ture in the controller s web interface 3 Address Too High The module address is above the maximum number available on the system controller To clear this error change the address to one within the ran...

Page 17: ...t 6 Reader Connection and 12VDC Pass Through Port 2 Reader Connection and 12VDC Pass Through Port 5 Reader Connection and 12VDC Pass Through Port 1 Reader Connection and 12VDC Pass Through Port 8 Read...

Page 18: ...details needed to help ensure correct installation and mounting All measurements are shown in millimeters 90 00 78 40 44 68 67 18 4 67 Screw Hole 39 20 39 20 78 40 17 55 35 40 Back Front PRT F2F8 DIN...

Page 19: ...0 to 55 C 14 to 131 F Storage Temperature 10 to 85 C 14 to 185 F Humidity 0 93 non condensing indoor use only relative humidity Mean Time Between Failures MTBF 622 997 hours calculated using RFD 2000...

Page 20: ...ral Product Statement The RCM compliance label indicates that the supplier of the device asserts that it complies with all applicable standards PRT F2F8 DIN Protege Half DIN Rail 8 Port F 2F Reader Ex...

Page 21: ...r local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accordance with your national legislation For busi...

Page 22: ...input for masking To comply with EN 50131 1 Do not fit more than 10 unpowered detectors per input Do not fit more than one non latching powered detector per input Do not mix unpowered detectors and no...

Page 23: ...neral Product Statement The UKCA Compliance Label indicates that the supplier of the device asserts that it complies with all applicable standards PRT F2F8 DIN Protege Half DIN Rail 8 Port F 2F Reader...

Page 24: ...evice may not cause harmful interference This device must accept any interference received including interference that may cause undesired operation NOTE THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES...

Page 25: ...lass A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada CAN ICES 3 A NMB 3 A PRT F2F8 DIN Protege Half DIN Rail 8 Port F...

Page 26: ...iable under any circumstances to any party in respect of decisions or actions they may make as a result of using this information In accordance with the ICT policy of enhanced development design and s...

Page 27: ...aimer Whilst every effort has been made to ensure accuracy in the representation of this product neither Integrated Control Technology Ltd nor its employees shall be liable under any circumstances to...

Reviews: