PRODUCT SPECIFICATIONS 

 

AC Input (IEC C 14 connector): 

110 to 254Vac 50/60Hz 

 
Input Power Factor: 

0.99 typ (120Vac input) 

 
Peak Efficiency (typical): 

90% 

 
Output V Line Regulation: 

+/- 0.1% 

 
Output V Load Regulation: 

+/- 1% 

 

Model: 

12V 

100A 

12V 
50A 

24V 
50A 

24V 
25A 

48V 
25A 

48V 

12.5A 

Output Voltage 

2

 (Nominal 

Battery float Voltage) (+/- 
0.5%) 

13.8V 

13.8V 

27.6V 

27.6V 

55.2V 

55.2V 

Max Current Limit  
(+5%, -0%) 

100A 

50A 

50A 

25A 

25A 

12.5A 

Continuous Current Rating  

87A 

50A 

44A 

25A 

22A 

12.5A 

Output Power (max)

 3

 

1200W 

690W 

1200W 

690W 

1200W 

690W 

Output Noise (max mVrms)  

30 

30 

30 

30 

40 

40 

Input Current (max at 
120Vac) 

12A 

7A 

12A 

7A 

12A 

7A 

LVD Threshold V (Default) 

11.5V 

11.5V 

23.0V 

23.0V 

46.0V 

46.0V 

LVD Reconnect V (Default) 

12.5V 

12.5V 

25.0V 

25.0V 

50.0V 

50.0V 

Idle DC Power Draw

4

 

<200mW 

<200mW 

<200mW 

<200mW 

<350mW 

<350mW 

 

Output Grounding: 

Floating, may be connected 
with Positive or Negative 
ground 

 
Alarm Output:   

Form-C contact, 0.5A 60Vdc 
max 

Remote Shutdown: 

2.5 to 16V signal to disable 
output 

 

                                                 

2

 

Actual Operating point may be lower due to battery charge requirement

 

3

 

Output power will be limited to approximately 1080W when operating with AC input voltage less than 

110Vac

 

4

 

AC mains power off; backup battery connected; LVD open

 

Summary of Contents for Pro Series

Page 1: ...upply INSTRUCTION MANUAL 855 343 001 Innovative Circuit Technology Ltd Models ICT690 12S ICT690 12SB ICT690 24S ICT690 24SB ICT690 48S ICT690 48SB ICT1190 12S ICT1190 12SB ICT1190 24S ICT1190 24SB ICT...

Page 2: ...cuit breaker Ensure battery polarity is correct before connecting Do not attempt to charge a frozen battery Handle batteries with care never short circuit battery terminals CAUTION Risk of personal in...

Page 3: ...Innovative Circuit Technology Ltd 3 Table of Contents INTRODUCTION 4 CHECK and CONFIGURE UNIT 4 INSTALLATION 6 OPERATION 7 Status Indicators and Alarms 9 PRODUCT SPECIFICATIONS 10 LIMITED WARRANTY 12...

Page 4: ...on B Remote on off control input for external control of the output Floating Form C alarm contact output supports remote monitoring of unit operation Model1 Output Voltage V Max Output Current A Conti...

Page 5: ...Pro Series unit must be protected using an outlet with a branch rated circuit breaker of 20A or lower value Connection Diagram Showing Rear Connectors and SW Switch 1 4 Configure the Output Settings A...

Page 6: ...sconnect Reconnect V Switch Settings 1 UP 0 Down x either INSTALLATION Mount the unit in a standard 19 inch equipment rack ensuring side air vents are not blocked using rack mounting screws not suppli...

Page 7: ...Connect the remote on off control or unit form C alarm contact monitoring wiring to the REMOTE connector if needed as shown in the following table Pin Number Name Function 1 Shutdown Remote output sh...

Page 8: ...able on page 5 while the output voltage will be determined by the battery state of charge and will rise to the output float voltage over time The battery will be maintained at the supply output float...

Page 9: ...l Battery power only CLOSED ON Battery Low when AC Off Triggers when battery voltage falls below the LVD threshold OFF OPEN ON System Fault Indicates internal circuit fault Clears when all fault condi...

Page 10: ...0W 690W 1200W 690W 1200W 690W Output Noise max mVrms 30 30 30 30 40 40 Input Current max at 120Vac 12A 7A 12A 7A 12A 7A LVD Threshold V Default 11 5V 11 5V 23 0V 23 0V 46 0V 46 0V LVD Reconnect V Defa...

Page 11: ...nst harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause...

Page 12: ...repair The Purchaser shall at their own risk and cost return the defective product to ICT s factory or designated repair center once an RMA is issued by ICT Return of the products to the customer afte...

Page 13: ...nce or causes external to the unit including but not limited to general environmental conditions such as rust corrosive atmospheres sustained temperatures outside the specified operating range of the...

Reviews: