Innovative Circuit Technology Ltd.
24
Control Panel display.
6.
System
Settings screen. The Output Voltage, Current Limit, and Output
Enable of all units are set in unison here. The Output Settings
screen on all of the Slave units will be locked out.
4.4. Advanced Parallel Operation with TCP/IP
Ethernet Connection
View the following settings and information on the Device Setup page
using a TCP/IP Ethernet connection to a unit: (see section 5)
Parallel Mode:
This field sets the Parallel Mode of the power supply
to Master, Slave, or Standalone. The Parallel Mode can also be set
from the Control Panel.
Device ID:
This field sets the unique Device ID (number between 0
and 5) for parallel operation of the power supply. The Device ID can
also be set from the Control Panel.
Send Slave Alarm Emails:
If this box is checked while this power
supply is operating as Master unit, the Master will send out alarm
notification e-mails when an alarm occurs on a Slave unit. This
feature is useful if your site has a limited number of Ethernet network
ports available and you only connect the Master unit to the Ethernet
network.
This box will have no effect if the unit is configured as a Slave or
Standalone unit
If this feature is enabled, check the Send E-mail boxes on the
Alarm Setup page for the alarms you wish to
receive e-mail notifications for
Parallel Errors:
Displays any errors or alarm conditions related to
the serial SHARE interface that are currently active.